2006-03-10 00:00:00 | BUILDING REVIEW CHECKLIST: |
| 1- PAY IMPACT FEES TO PALM BEACH COUNTY. |
| BRING BACK STAMPED DRAWINGS AND PAID |
| RECEIPT. |
| |
| 2- PROVIDE DRAINAGE PLANS AS REQUIRED BY |
| SEC. R401.3 OF 2004 RESIDENTIAL CODE. |
| |
| 3- PROVIDE STRUCTURAL BUCK DETAIL USING |
| 2X BUCK AS REQUIRED BY ENTRY DOOR |
| PRODUCT APPROVAL SUBMITTED. SEE SECTION |
| R613.6.2 2004 RESIDENTIAL CODE FOR |
| PROPER BUCK INSTALLATION. |
| |
| 4- OWES $351.21 FOR UPDATED VALUATION |
| AND RADON FEES. |
| |
| 5- PROVIDE SPECS/DETAILS FOR |
| INSTALLATION OF DECORATIVE STORM |
| SHUTTERS. SEC. 106.1.2 CITY AMENDMENTS |
| TO FBC 2004. |
| |
| 6- DRAWINGS S-2 AND S-3 ARE MISSING THE |
| ENGINEER'S INFORMATION AS REQUIRED BY |
| CHAPTER 471 FLORIDA STATUTES. |
| |
| 7- A) PROVIDE FLORIDA OR LOCAL PRODUCT |
| APPROVAL FOR SLIDING GLASS DOORS AND |
| FRENCH DOORS WITH TRANSOM ABOVE SINGLE |
| UNIT AS SHOWN ON PLANS OR PROVIDE |
| COMPLETE INFORMATION FOR STRUCTURAL |
| MULLION AS REQUIRED BY SEC. R613.7 2004 |
| RESIDENTIAL CODE. |
| B) SPECIFY SIZE OF FIXED WINDOW. |
| |
| 8- ARCHITECT TO PROVIDE ALLINFORMATION |
| ON TITLE BLOCK AS REQUIRED BY CHAPTER |
| 481 FLORIDA STATUTES AND 61G1-16.004 OF |
| ADMINISTRATIVE CODE. SEE ATTACHED COPY. |
| |
| 9- PROVIDE FLORIDA OR LOCAL PRODUCT |
| APPROVAL AS REQUIRED BY RULE 9B-72 FOR: |
| A) FRENCH DOORS WITH TRANSOM ABOVE. |
| OR FRENCH DOORS ALONE. SEE ITEM #7 ABOVE |
| B) SLIDING GLASS DOORS WITH TRANSOM |
| ABOVE. OR SLIDING GLASS DOORS ALONE. SEE |
| ITEM #7 ABOVE. |
| C) STRUCTURAL MULLIONS. SEE ITEM #7. |
| D) FIXED WINDOWS. SEE ITEM #7 ABOVE. |
| E) ALL TRUSS CONNECTORS. SEE PLANS. |
| F) SINGLE HUNG WINDOWS. DADE COUNTY |
| NOA TO MATCH NOA SUBMITTED FOR FLORIDA |
| PRODUCT APPROVAL. VISIT |
| WWW.FLORIDABUILDING.ORG TO DOWNLOAD |
| CORRESPONDING NOA. |
| G) ROOF SHINGLES. PROVIDE SAME NOA |
| SUBMITTED FOR FLORIDA PRODUCT APPROVAL. |
| H) PRECAST LINTELS. |
| I) ALUMINUM VENTS. |
| J) ALUMINUM SIDING. |
| |
| 10- DESIGNER OF RECORD TO REVIEW AND |
| APPROVE IN WRITTING ALL PRODUCT |
| APPROVALS PRIOR TO SUBMITTAL TO THIS |
| OFFICE AS REQUIRED BY SEC. 106.3.3 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| 11- DRAWING 1: UPDATE BUILDING CODE |
| DATA. SEE 2004 RESIDENTIAL CODE. |
| |
| 12- DRAWING A-1: A) WINDOW C (3'-0" X |
| 4'-0") DOESN'T MEET THE EGRESS |
| REQUIREMENTS OF SEC. R310.1.2 2004 |
| RESIDENTIAL CODE. |
| B) SPECIFY SAFETY GLASS FOR WINDOW IN |
| BATHROOM. SEE PLANS. SEC. R308.4 2004 |
| RESIDENTIAL CODE. |
| C) UPDATE CODE REFERENCE FOR ATTIC |
| ACCESS. SEE 2004 RESIDENTIAL CODE. |
| D) UPDATE CODE REFERENCES SPECIFIED |
| ON GENERAL NOTES AND SCHEDULE NOTES. SEE |
| 2004 RESIDENTIAL CODE. |
| |
| 13- DRAWING A-2: A) DESIGN PRESSURES |
| MARK DOESN'T MATCH MARK SHOWED ON DOORS |
| AND WINDOWS OPENINGS. REVISE AS REQ'D. |
| B) SPECIFY SIZE OF MANUFACTURED |
| ALUMINUM LOUVER AT FRONT AND BACK. SEC. |
| 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| 14- DRAWING A-3: A) WHERE IS DETAIL A-5" |
| SPECIFIED ON PLANS? |
| B) SECTION "A": 1) THERE IS NOT |
| ARCHED PORCH BEAM. REVISE AS REQUIRED. |
| 2) WHERE IS DETAIL SHT 5? |
| 3) SPECIFIED FIREBLOCKING MATERIAL |
| AND LOCATION AT CONCEALED SPACES IN |
| SOFFITS AND WALLS. SEE PLANS. SEC. |
| R602.8 2004 RESIDENTIAL CODE. |
| |
| 15- DRAWING A-4: A) WALL SECTION "A". |
| UPDATE CODE REFERENCE SPECIFIED FOR |
| FIREBLOCKING AND SPECIFY FIREBLOCKING |
| MATERIAL. SEE 2004 RESIDENTIAL CODE. |
| B) WALL SECTION "B". FOUNDATION PLAN |
| DOESN'T MATCH PLANS. REVISE AS REQUIRED. |
| C) PORCH BEAM IS NOT AN ARCHED BEAM. |
| REVISE AS REQUIRED. SEE PLANS. |
| |
| 16- DRAWING S-1: A) PROVIDE COMPLETE |
| DETAILS AND SPECS FOR WOOD DECK AND WOOD |
| STEPS AT REAR AREA OUTSIDE MASTER |
| BEDROOM AND AT COVERED PORCH. |
| B) ROOF FRAMING PLAN CALLS FOR TRUSS |
| ANCHOR A3 BY REAR PORCH. THERE IS NOT |
| A3. REVISE AS REQUIRED. |
| C) WHERE ARE DETAILS A, C AND E? |
| D) WWHERE IS DET 2 SHT S-2?. |
| KEY DETAILS TO MATCH DRAWINGS. |
| |
| 17- DRAWING S-2: A) TYP. 1 STORY |
| SECTION: SPECIFY SIZE AND LOCATION OF |
| ATTIC VENTS. ALSO, CONSIDER ALUMINUM |
| VENTS FOR TOTAL VENTING AREA REQUIRED. |
| SEC. R806 2004 RESIDENTIAL CODE. |
| B) DETAIL D: 1) HOW IS 2"X6" SILL |
| PLATE ATTACHED TO CONCRETE BEAM? |
| 2) HOW IS 2" X 6" "L" BRACE NAILED TO |
| BOTTOM SILL? |
| 3) USP TA18 IS SHOWN AS BEING |
| ATTACHED TO CONCRETE BEAM. THIS |
| CONNECTOR IS TO BE EMBEDED IN CONCRETE. |
| REVISE AS REQUIRED. SEE USP CATALOGUE. |
| 4) DETAIL A: SHOW COMPLETE DETAILS |
| AND SPECS FOR CONCRETE STEPS AT ENTRY |
| PORCH. |
| |
| 18- DRAWING S-3: A) GENERAL NOTES: |
| UPDATE ALL REFERENCE STANDARDS AND |
| SPECIFIC EDITION TO BE USED. SEE 2004 |
| RESIDENTIAL CODE AND 2004 FBC. |
| B) UPDATE CODE SECTIONS REFERENCED |
| FOR WIND LOADS, EMERGENCY EGRESS AND |
| GLASS IMPACT PROTECTION NOTES. |
| C) VENTILATION AND EGRESS ARE TWO |
| DIFFERENT CODE ISSUES.REVISE AS REQ'D. |
| D) TRUSS ANCHOR SCHEDULE: NUMBER OF |
| NAILS AND UPLIFT LOADS TO MATCH CURRENT |
| USP CATALOGUE. OTHERWISE, PROVIDE |
| COMPLETE ENGINEERING ANALYSIS FOR NUMBER |
| AND UPLIFT LOADS THAT DIFFER THOSE |
| PUBLISHED BY MANUFACTURER. SEC. 106.1.2 |
| CITY AMENDMENTS TO FBC 2004. |
| E) DELETE NOTES CORRESPONDING TO |
| STRUCTURE ADDITIONS. THEY DON'T APPLY TO |
| THIS PROJECT. |
| |
| 19- SURVEY TO HAVE SURVEYOR'S ORIGINAL |
| SIGNATURE, NOT COPY, AS REQUIRED BY |
| CHAPTER 472 FLORIDA STATUTES. |
| |
| 20- STORM SHUTTERS: |
| A) PROVIDE KEY PLAN. |
| B) PROVIDE COMPLETE INSTALLATION |
| SCHEDULE. SEE ATTACHED SAMPLE. PROVIDE |
| ALL INFORMATION. |
| |
| 21- ENERGY CALCULATIONS: |
| A) USE 2004 FORM, NOT 2001. |
| B) BUILDING ORIENTATION, OVERHANG |
| LENGTH AND HEIGHT AND AREA DON'T MATCH |
| PLANS. REVISE AS REQUIRED. SEE CHAPTER |
| 13 FBC 2004 FOR PRROPER WAY OF |
| CALCULATING ENERGY CALCS. REVISE AS |
| REQUIRED. |
| ***NOTE: IF ENERGY CALCULATIONS ARE NOT |
| DONE FOR WORST CASE SCENARIO, THEN THEY |
| MUST BE DONE ACCORDING TO THE ACTUAL |
| HOUSE ORIENTATION. SEE SURVEY FOR |
| CORRECT ORIENTATION. |
| C) OWNER/AGENT TO SIGN BOTTOM OF FORM |
| |
| JULIO GOMEZ |
| BUILDING PLANS EXAMINER |
| (561)805-6712 |