2006-02-28 00:00:00 
 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 2) M1506.3 VENTILATION RATE.
 VENTILATION SYSTEMS SHALL BE DESIGNED TO
 HAVE THE CAPACITY TO EXHAUST THE MINIMUM
 AIR FLOW RATE DETERMINED IN ACCORDANCE
 WITH TABLE M1506.3 .
 TABLE M1506.3
 MINIMUM REQUIRED EXHAUST RATES FOR
 ONE- AND TWO-FAMILY DWELLINGS
 AREA TO BE VENTILATEDVENTILATION RATES
  
 KITCHENS100 CFM INTERMITTENT OR
 25 CFM CONTINUOUS
 BATHROOMS?TOILET ROOMSMECHANICAL
 EXHAUST CAPACITY OF
 50 CFM INTERMITTENT OR 20 CFM
 CONTINUOUS.
  
  
 R802.10.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN
 CONFORMANCE WITH SECTION R802.10.1 ,
 SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. TRUSS DESIGN DRAWINGS
 SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS
 DESIGN DRAWING SHALL BE PROVIDED WITH
 THE SHIPMENT OF TRUSSES DELIVERED TO THE
 JOBSITE
  
 4) PLEASE SEE ZONING NOTE ABOUT THE TWO
 ENTRANCE DOORS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  