2006-04-07 00:00:00****CORRECTIONS****
 ****SECOND REVIEW****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST, NUMBERING REMAINING
 THE SAME FOR CONSISTENCY
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 THIS IS REQUIRED PRIOR TO PERMIT PICKUP.
  
 2.)ADDRESSED.
  
 3.)PROVIDE A SOILS INVESTIGATION
 REPORT, FBC1808.2.
  
 THIS WAS ADDRESSED; HOWEVER, THE SOILS
 REPORT GIVES FOUNDATION RECOMMENDATIONS
 FOR THE FUTURE GARAGE AND HIGH RISE.
 THERE IS NO RECOMMENDATION FOR THE SALES
 TRAILER TIE DOWN, AND THE ENGINEER FOR
 THE SALES TRAILER FOUNDATION DOES NOT
 REFER TO ANY SOILS ENGINEERING IN HIS
 PLAN.
  
 AS DISCUSSED, PLEASE HAVE THE ENGINEER
 CALL ME.A LETTER OR A PLAN REVISION
 REFERENCING THE SOILS REPORT WILL BE
 REQUIRED.PLEASE NOTE THAT I HAVE
 ATTEMPTED REACHING THE ENGINEER, WILLIAM
 MCCANN PE, CLEARWATER, AND THE TELEPHONE
 NUMBER ON HIS TITLE BLOCK IS
 DISCONNECTED.
  
 IN THE LETTER OR PLAN REVISION, THE
 ENGINEER IS TO ADDRESS THE TWO ISSUES OF
 BEARING PRESSURE AND UPLIFT RESISTANCE
 FOR THE ANCHORS SPECIFIC TO THE SITE.
 THE FOUNDATION PLAN FD1 DOES NOT REFER
 TO THE JOB SITE IN ANY WAY (JOB NAME,
 ADDRESS OR LEGAL DESCRIPTION) SO I
 CANNOT DETERMINE WHETHER OR NOT THIS IS
 A STANDARD DETAIL OR IF THE ENGINEER IS
 AWARE OF SITE SPECIFIC SOIL CONDITIONS.
  
 ADDITIONALLY, THE FOUNDATION ENGINEER
 HAS DECLARED 140 EXPOSURE B.WHEN
 ADDRESSING SOILS CONDITIONS, ALSO HAVE
 THE ENGINEER ADDRESS SITE CONDITION IN
 REGARDS TO WIND EXPOSURE.
  
  
 THE FOLLOWING COMMENTS REMAIN;
 INFORMATIONAL ONLY TO ASSIST IN PLAN
 REVIEW FOR THE FUTURE SALES TRAILER
  
 4.)THIS FOUNDATION AND TIE DOWN ONLY
 PERMIT WILL BE ISSUED AT THE
 CONTRACTOR'S RISK.BUILDING CODE
 COMPLIANCE FOR THE OTHER ITEMS (SALES
 TRAILER, ACCESSIBLE ROUTE, ETC.) CANNOT
 BE DETERMINED BASED ON THE INFORMATION
 PROVIDED.
  
 5.)THE ARCHITECTURAL SITE PLAN
 CONFLICTS WITH THE CIVILS.THE
 ARCHITECTURAL SITE PLAN SHOWS ONE LOT;
 THE OTHER SHEETS SHOW MULTIPLE LOTS.
 HAS A UNITY OF TITLE BEEN RECORDED?
 NOTE THAT THE FUTURE TRAILER APPEARS TO
 BE LESS THAN 5' FROM THE CURRENT
 PROPERTY LINE AND THAT THE OTHER
 IMPROVEMENTS CROSS OVER THE PROPERTY
 LINES.
  
 THIS COMMENT IS INFORMATIONAL AND DOES
 NOT PREVENT THIS PERMIT FROM BEING
 ISSUED.HOWEVER, BEFORE A BUILDING
 PERMIT FOR THE SALES TRAILER AND OTHER
 IMPROVEMENTS CAN BE ISSUED A RECORDED
 UNITY OF TITLE WILL BE REQUIRED.
  
 6.)THIS PARCEL IS IN A FLOOD ZONE.
 CITY OF WEST PALM BEACH MUNICIPAL CODE
 94-546(B), FINISHED FLOOR MUST BE 6"
 ABOVE BFE AND AN ELEVATION CERTIFICATE
 WILL BE REQUIRED.THIS COMMENT IS
 INFORMATIONAL AND DOES NOT NEED TO BE
 ADDRESSED.
  
 *************************
  
 4/7/6S/W ENGINEER, 727-461-5500