Date |
Text |
2006-04-07 00:00:00 | ****CORRECTIONS**** |
| ****SECOND REVIEW**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBCFLORIDA BUILDING CODE 2004 |
| FBC EBFLORIDA BUILDING CODE 2004 |
| EXISTING BUILDING CODE |
| FBC*CITY OF WEST PALM BEACH |
| AMENDMENTS TO THE FBC2004 |
| |
| FROM PREVIOUS LIST, NUMBERING REMAINING |
| THE SAME FOR CONSISTENCY |
| |
| 1.)A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| THIS IS REQUIRED PRIOR TO PERMIT PICKUP. |
| |
| 2.)ADDRESSED. |
| |
| 3.)PROVIDE A SOILS INVESTIGATION |
| REPORT, FBC1808.2. |
| |
| THIS WAS ADDRESSED; HOWEVER, THE SOILS |
| REPORT GIVES FOUNDATION RECOMMENDATIONS |
| FOR THE FUTURE GARAGE AND HIGH RISE. |
| THERE IS NO RECOMMENDATION FOR THE SALES |
| TRAILER TIE DOWN, AND THE ENGINEER FOR |
| THE SALES TRAILER FOUNDATION DOES NOT |
| REFER TO ANY SOILS ENGINEERING IN HIS |
| PLAN. |
| |
| AS DISCUSSED, PLEASE HAVE THE ENGINEER |
| CALL ME.A LETTER OR A PLAN REVISION |
| REFERENCING THE SOILS REPORT WILL BE |
| REQUIRED.PLEASE NOTE THAT I HAVE |
| ATTEMPTED REACHING THE ENGINEER, WILLIAM |
| MCCANN PE, CLEARWATER, AND THE TELEPHONE |
| NUMBER ON HIS TITLE BLOCK IS |
| DISCONNECTED. |
| |
| IN THE LETTER OR PLAN REVISION, THE |
| ENGINEER IS TO ADDRESS THE TWO ISSUES OF |
| BEARING PRESSURE AND UPLIFT RESISTANCE |
| FOR THE ANCHORS SPECIFIC TO THE SITE. |
| THE FOUNDATION PLAN FD1 DOES NOT REFER |
| TO THE JOB SITE IN ANY WAY (JOB NAME, |
| ADDRESS OR LEGAL DESCRIPTION) SO I |
| CANNOT DETERMINE WHETHER OR NOT THIS IS |
| A STANDARD DETAIL OR IF THE ENGINEER IS |
| AWARE OF SITE SPECIFIC SOIL CONDITIONS. |
| |
| ADDITIONALLY, THE FOUNDATION ENGINEER |
| HAS DECLARED 140 EXPOSURE B.WHEN |
| ADDRESSING SOILS CONDITIONS, ALSO HAVE |
| THE ENGINEER ADDRESS SITE CONDITION IN |
| REGARDS TO WIND EXPOSURE. |
| |
| |
| THE FOLLOWING COMMENTS REMAIN; |
| INFORMATIONAL ONLY TO ASSIST IN PLAN |
| REVIEW FOR THE FUTURE SALES TRAILER |
| |
| 4.)THIS FOUNDATION AND TIE DOWN ONLY |
| PERMIT WILL BE ISSUED AT THE |
| CONTRACTOR'S RISK.BUILDING CODE |
| COMPLIANCE FOR THE OTHER ITEMS (SALES |
| TRAILER, ACCESSIBLE ROUTE, ETC.) CANNOT |
| BE DETERMINED BASED ON THE INFORMATION |
| PROVIDED. |
| |
| 5.)THE ARCHITECTURAL SITE PLAN |
| CONFLICTS WITH THE CIVILS.THE |
| ARCHITECTURAL SITE PLAN SHOWS ONE LOT; |
| THE OTHER SHEETS SHOW MULTIPLE LOTS. |
| HAS A UNITY OF TITLE BEEN RECORDED? |
| NOTE THAT THE FUTURE TRAILER APPEARS TO |
| BE LESS THAN 5' FROM THE CURRENT |
| PROPERTY LINE AND THAT THE OTHER |
| IMPROVEMENTS CROSS OVER THE PROPERTY |
| LINES. |
| |
| THIS COMMENT IS INFORMATIONAL AND DOES |
| NOT PREVENT THIS PERMIT FROM BEING |
| ISSUED.HOWEVER, BEFORE A BUILDING |
| PERMIT FOR THE SALES TRAILER AND OTHER |
| IMPROVEMENTS CAN BE ISSUED A RECORDED |
| UNITY OF TITLE WILL BE REQUIRED. |
| |
| 6.)THIS PARCEL IS IN A FLOOD ZONE. |
| CITY OF WEST PALM BEACH MUNICIPAL CODE |
| 94-546(B), FINISHED FLOOR MUST BE 6" |
| ABOVE BFE AND AN ELEVATION CERTIFICATE |
| WILL BE REQUIRED.THIS COMMENT IS |
| INFORMATIONAL AND DOES NOT NEED TO BE |
| ADDRESSED. |
| |
| ************************* |
| |
| 4/7/6S/W ENGINEER, 727-461-5500 |