Plan Review Notes For Permit 05120987 |
Permit Number |
05120987 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2006-10-12 16:46:34 | | | DENIED BY BUILDING | | | | 1)THE SURVEY AND SITE PLANS DO NOT LOCATE THE | | CONDO/PROPERTY LINES 20 FEET FROM THE PARKING STRUCTURE | | AS REQUIRED BY 2004 FBC 903.6.1(2). SEE COMMENT #4 FROM | | PREVIOUS REVIEW. | | | | 2)THE LOCATION OF THE CONDO/PROPERTYLINES DO NOT | | APPEAR TO BEGREATER THAN 10 FEET AS REQUIRED BY FBC | | TABLE 708.4 FOOTNOTE (C) SUCH THAT THE AREA OF OPENINGS | | IS NOT LIMITED. SEE COMMENT #2 FROM PREVIOUS REVIEW. | | | | 3)THE SQUARE FOOTAGE ANALYSIS ON A2.0.1 STILL LISTS | | BUSINESS AND STORAGE OCCUPANCIES ON THE FIRST FLOOR. | | | | 4) SHEETS A3.2.2 AND A4.1.2 SPECIFY 3PLY MODIFIED ROOF | | COVERING. THE PRODUCT APPROVAL THAT WAS SUBMITTED IS | | FOR A BUILT UP ROOF SYSTEM. PLEASE CORRECT. | | | | 5) DETAIL 2 ON A1.1.0 SPECIFIES AN 8' HIGH GENERATOR | | SCREEN WALL AND THE SITE PLANS ON A 1.1.0 AND A1.1.1 | | SHOW THE WALL AS6'. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|