Plan Review Notes For Permit 05120152 |
Permit Number |
05120152 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2006-02-06 00:00:00 | DENIED 2ND TIME | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | 1) FBC-2004 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (NOTE:STILL NEED | | MANUFACTURE SHEETS WITH THIRD PARTY | | LISTING THE INFORMATION YOU HAVE | | SUBMITTED ARE SPEC SHEETS) | | 2) FBC-2004 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF.(NOTE: STILL NEED MANUFACTURE CUT | | SHEET SUBMITTAL IF ONE CANNOT BE FOUND | | AN EXTERNAL HARTFORD LOOP SHALL BE | | PROVIDED AND SHOWN ON PIPING SCHEMATIC.) | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561)805-6730 | | FAX (561)805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561)805-6721 | | | | . |
|