Plan Review Notes
Plan Review Notes For Permit 05120152
Permit Number 05120152
Review Stop P
Sequence Number 1
Notes
Date Text
2005-12-29 00:00:00DENIED
  
 REFERENCE: FBC-2004424.2 SWIMMING
 POOLS.
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR POOL PLUMBING PERMIT:
 1) THE PIPING SCHEMATIC SHOWS ONLY ONE
 MAIN DRAIN TO THE POOL WITH A 1" VENT.
 THERE SHOULD ALSO BE A MAIN DRAIN SHOWN
 FOR THE SPA WITH A 1-1/2" VENT.PLEASE
 CORRECT THE PIPING SCHEMATIC DRAWING TO
 SHOW BOTH MAIN DRAINS ON SCHEMATIC.
 2) COMPLY WITH FBC-2004 SEC 424.2
 PRIVATE SWIMMING POOLS.(ADD TO NOTES)
 3) FBC-2004 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 4) FBC-2004 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
  