 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 UNSAT
 PREVIOUS COMMENT DATED 3-4-06 #8
  
 NO DOORS ON BASE OF CABNET.
  
  
 8. BREAK ROOM SINK SHALL COMPLY WITH
 11-4.24 AND ALL SUBSECTIONS.
 SUBMIT A DETAIL SHOWING COMPLIANCE.
 A. 11-4.24.2 HEIGHT
 B. 11-4.24.3 KNEE CLEARANCE
 D. 11-4.24.5 CLEAR FLOOR SPACE
  
 (FORWARD APPROACH, EXTENDING A MAXIMUM
 OF 19" UNDERNEATH THE SINK REQUIRED).
  
 E. 11-4.24.6 EXPOSED PIPES AND SURFACES
  
 END OF COMMENTS, QUESTIONS 561-805-6692