Date |
Text |
2008-11-24 12:07:27 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| CODE |
| FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| FAC FLORIDA ADMINISTRATIVE CODE |
| FS FLORIDA STATUTE |
| |
| 1. SALES 101B, PLEASE SHOW MANEUVERING CLEARANCE FBC |
| FIGURE 11-25, PULL SIDE. THE DETAIL PROVIDED 17 A5.2 IS |
| NOT CLEAR AS TO WHAT THE OUTER BOX REPRESENTS; IS THIS |
| THE DRYWALL OVER THE COLUMN, OR SOMETHING ELSE NOT |
| SHOWN ON THE DETAIL? THIS APPEARS TO ENTIRELY OBSTRUCT |
| THE MANEUVERING CLEARANCE SPACE REQUIRED. |
| |
| 2. PROVIDE A REVISED VALUATION FOR THIS JOB. |
| |
| 3. SEE A7.0, FBC11-4.16.2. CENTERLINE OF THE FIXTURE TO |
| BE AT 18"; GENERAL MGR RESTROOM, RETAIL BOUTIQUE, MENS |
| 147, WOMENS 103 SHOW THE 18" DIMENSION REQUIRED BUT THE |
| FIXTURE IS NOT CENTERED AT THIS DIMENSION. |
| |
| 4. A7.1, PROVIDE A BACKING DETAIL. IT IS REFERENCED |
| (STATES THAT BACKING IS REQUIRED) BUT A DETAIL WHICH |
| WILL PROVIDE THE STRENGTH REQUIRED TO SUPPORT A FUTURE |
| GRAB BAR WAS NOT PROVIDED. |
| |
| 5. 1-ID11.6A, SEE 11-4.7.2; ONE COUNTER SHOWN AT 3'6", |
| DIMENSIONS NOT PROVIDED FOR OTHER COUNTERS. PLEASE |
| PROVIDE INFORMATION REGARDING USE OF THESE COUNTERTOPS |
| TO DETERMINE WHETHER OR NOT THEY SHOULD COMPLY WITH |
| FBC11-4.7.2 (36" HEIGHT FOR A PORTION OF THE |
| COUNTERTOP). |
| |
| 6. PLEASE PROVIDE A LETTER STATING THAT THE SUCCESSOR |
| ARCHITECT HAS FOLLOWED THE PROCEDURES OF FAC61G1-18.002 |
| (TAKES FULL RESPNOSIBILITY, HAS RECREATED THE WORK, |
| ETC.) OR PROVIDE NEW SIGNED AND SEALED DRAWINGS. |
| |
| IF THE ABOVE ITEMS DO NOT AFFECT OTHER TRADES, ALL OF |
| THE ABOVE ITEMS CAN BE PROVISO OR REDLINE ITEMS UPON |
| REQUEST. PLEASE CONTACT ME TO DISCUSS IF YOU WISH TO |
| REQUEST THIS OPTION. |
| |