Plan Review Notes
Plan Review Notes For Permit 05111008
Permit Number 05111008
Review Stop B
Sequence Number 1
Notes
Date Text
2005-12-01 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05111008
 ADD: 4200 N FLAGLER DR
 CONT:CENTEX
 TEL: (561)2289-0276
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS NEED TO BE UPDATED TO THE 2004
 FL BLDG CODE. THE FOLLOWING ITEMS NEED
 TO REFLECT THE REQUIREMENTS OF 110.2.*
 1A) THE EDITION OF THE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 1B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3 .
 1C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6 .
 1D)THE DESIGN OCCUPANT LOAD.
 1E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 1F) ANY SPECIAL STIPULATIONS AND
 CONDITIONS OF THE BUILDING PERMIT.
  
 2) SEE TABLE 601 & 602 FOR NEW BLDG
 CLASSIFICATION, FIRE REISITANT
 REQUIREMENTS PLEASE CORRECT.
  
 3) SEE TABLE 503 FOR ALLOWABLE HEIGHT &
 AREA.
  
 4)UPDATE PLANS TO THE 2004 CODE FOR
 T803.3 SEE TABLE 803.5.
 803.5 INTERIOR FINISH REQUIREMENTS BASED
 ON GROUP.
 INTERIOR WALL AND CEILING FINISH SHALL
 HAVE A FLAME SPREAD INDEX NOT GREATER
 THAN THAT SPECIFIED IN TABLE 803.5 FOR
 THE GROUP AND LOCATION DESIGNATED.
 INTERIOR WALL AND CEILING FINISH
 MATERIALS, OTHER THAN TEXTILES, TESTED
 IN ACCORDANCE WITH NFPA 286 AND MEETING
 THE ACCEPTANCE CRITERIA OF SECTION
 803.2.1 , SHALL BE PERMITTED TO BE USED
 WHERE A CLASS A CLASSIFICATION IN
 ACCORDANCE WITH ASTM E 84 IS REQUIRED.
 TABLE 803.5
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026