2005-12-19 00:00:00 | |
| |
| DENIED |
| |
| 1) THE NEW FRONT ENCLOSURE IS AN |
| ADDITION AND AS SUCH SHALL COMPLY WITH |
| THE PROVSIONS OF THE 2004 FL BLDG CODE |
| REMOVE GENERAL NOTE THAT SPEC'S UBC |
| |
| 2) WINDOWS SHALL BE IMPACT RESISTANT OR |
| MUST BE PROTECTED WITH APPROVED IMPACT |
| RESISTANT COVERINGS AS PER 1609.1.4 2004 |
| FBC |
| |
| 3) SUBMIT FRAMING DETAILS THAT SHOW |
| BACKING FOR STORM PANELS |
| |
| 4) SUBMIT DOOR AND WINDOW SIZES |
| |
| 5) SUBMIT DETAILS OF THE ROOF AND WALL |
| FRAMING ATTACHMENT TO EXISTING |
| |
| 6) SUBMIT DETAILS ON ALL FRAMING |
| CONNECTORS FOR STRAPPING/ANCHORING |
| |
| 7) SUBMIT AN ANCHOR SCHEDULE IN LIEU OF |
| PRODUCT APPROVALS FOR EACH CONNECTOR |
| BEING USED. SHOW THE APPROVED |
| MANUFACTURER,TYPE,SIZE,ETC. OF EACH |
| CONNECTOR |
| |
| 8) ROOFS WITH A PITCH FROM 2/12 TO 4/12 |
| REQUIRE DOUBLE UNDERLAYMENT PER 905.2.7 |
| 2004 FBC RES. |
| |
| 9) SUBMIT 2 COPIES OF THE PRODUCT |
| APPROVALS COMPLETE WITH THE FLORIDA |
| STATE APPROVAL COVER SHEETS AND PRODUCT |
| NOA'S. ROOFING AND STORM PANELS ALSO |
| REQUIRE PRODUCT APPROVAL |
| |
| 10) SUBMIT FOUNDATION PLAN, SHOW IF THE |
| FOUNDATION IS NEW OR EXISTING |
| |
| 11) FRONT DOOR AWNING SHALL COMPLY WITH |
| 3105. 2004 FBC AND 2 COPIES OF PRODUCT |
| APPROVAL SHALL BE SUBMITTED |
| |
| 12) SUBMIT 2 COPIES OFF ALL REQUIRED |
| DRAWINGS SIGNED BY THE PARTY RESPONSIBLE |
| FOR THE DRAWINGS THAT INDICATE |
| COMPLIANCE WITH THE 2004 FL BLDG CODE |
| |
| 13) NOTE THAT IF A FLOOR PLAN WITH |
| ELECTRICAL IS NOT SUBMITTED AN |
| ADDITIONAL PERMIT WILL BE REQUIRED |
| |
| 14) SUBMIT A RECORDED NOTICE OF |
| COMMENCEMENT PRIOR TO A PERMIT BEING |
| ISSUED |
| |
| 15) PALM BEACH COUNTY IMPACT FEES ARE |
| REQUIRED, THE 2 SETS OF PLANS SHALL BE |
| STAMPED BY THEM AND A COPY OF THE |
| RECEIPT SUBMITTED TO WPB CONSTRUCTION |
| SERVICES |
| |
| |