Date Text
2005-11-30 00:00:00DENIED
  
  
  
 1)OWNER OR OWNERS AGENT SHALL SUBMIT A
 NOTICE OF COMMENCEMENT BEFORE A PERMIT
 CAN BE ISSUED.
  
 2) THE NOA'S FOR PGT INDUSTRIES
 HORIZONTAL SLIDERS ARE INCOMPLETE DUE TO
 OFF CENTER PHOTOCOPIES. RE-SUBMIT CLEAR
 COPIES
  
 3) WHERE DOORS AND WINDOWS ARE ATTACHED
 TO WOOD BUCKS AND THE ATTACHMENT METHOD
 IS NOT SPECIFIED, THE ANCHORING
 PERFORMANCE SHALL BE EQUAL TO OR GREATER
 THAN THAT OF THE WINDOW OR DOOR ASSEMBLY
 ATTACHMENT AS DEMONSTRATED BY ACCEPTED
 ENGINEERING PRACTICES. R613.6.1 FBC.RES
  
 4) SPECIFY THE PANEL GAUGE, MOUNTING
 METHOD AND CONNECTION TYPE IN THE STORM
 PANEL NOA'S. ALSO PROVIDE A KEY PLAN
 WITH PANEL #'S AND WINDOW SIZES.
  
 5) PROVIDE A FLOOR PLAN WITH THE
 LOCATION OF BEDROOM WINDOWS AND OPENING
 SIZES FOR EMERGENCY EGRESS REQUIREMENTS.
  
 6)NOTE THAT THE JELD-WEN DOOR SPECIFIED
 IN THE PRODUCT APPROVAL CAN HAVE
 OPTIONAL SIDE LITES ATTACHED. IF USED
 IMPACT PROTECTION IS REQUIRED.
  
  
 BLDG PLAN REVIEW