Date |
Text |
2006-05-02 00:00:00 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| TO THE FBC2004 |
| |
| FROM PREVIOUS LISTS: |
| |
| 1.)A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| THE NOC PROVIDED IS EXPIRED, OVER 90 |
| DAYS WITHOUT COMMENCING WORK |
| FS713.13(2). |
| |
| 2.)PROVIDE BUILDING MEAN ROOF HEIGHT. |
| DESIGN PRESSURES FOR BUILDINGS OVER |
| 60FEET ARE REQUIRED TO BE DESIGNED USING |
| ASCE7, FBC1609.1.1.DOCUMENTS PREPARED |
| BY AN ENGINEER AND SUBMITTED FOR PUBLIC |
| RECORD ARE TO BE SIGNED SEALED ORIGINALS |
| FAC61G15-23.002. |
| |
| (SECOND REVIEW) THE SCHEDULE GIVES |
| DESIGN PRESSURES OF -13.5 AND -14.1, BUT |
| -45 IS CIRCLED ON SHEET 9 OF THE PRODUCT |
| APPROVAL.DESIGN PRESSURES ARE TO BE |
| DETERMINED BY FBC TABLE 1609.6B AND |
| 1609.6D. |
| |
| (THIRD REVIEW) A NEW SCHEDULE GIVES THE |
| WORST CASE PRESSURE AS -54.5 BUT PAGE 9 |
| HAS -45 CIRCLED.NO ANCHORING IS |
| SPECIFIED ON EITHER THE INSTALLATION |
| SCHEDULE OR ON THE TABLES ON THE PRODUCT |
| APPROVALS. |
| |
| 3.)ADDRESSED. |
| |
| 4.)COMPLETE THE ATTACHED INSTALLATION |
| SCHEDULE, OR PROVIDE REQUIRED |
| INFORMATION IN A SIMILAR FORMAT.SEE |
| ATTACHED POLICY. |
| |
| (SECOND REVIEW) THE FORM WAS NOT FILLED |
| OUT CORRECTLY (ALL COLUMNS BLANKEXCEPT |
| FOR DPS WHICH ARE INCORRECT).NO ANCHOR |
| SPACING INDICATED ON PRODUCT APPROVAL. |
| NOT ENOUGH INFORMATION PROVIDED TO |
| DETERMINE CODE COMPLIANCE. |
| |
| (THIRD REVIEW) SAME PAPERWORK SUBMITTED. |
| NO ANCHORING SPECIFIED. |
| |
| NEW COMMENT: |
| |
| 5.)ONLY ONE PRODUCT APPROVAL WAS |
| SUBMITTED. SUBMIT TWO COPIES OF ALL |
| DOCUMENTS FOR PERMITTING. |