2006-05-02 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 FROM PREVIOUS LISTS:
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 THE NOC PROVIDED IS EXPIRED, OVER 90
 DAYS WITHOUT COMMENCING WORK
 FS713.13(2).
  
 2.)PROVIDE BUILDING MEAN ROOF HEIGHT.
 DESIGN PRESSURES FOR BUILDINGS OVER
 60FEET ARE REQUIRED TO BE DESIGNED USING
 ASCE7, FBC1609.1.1.DOCUMENTS PREPARED
 BY AN ENGINEER AND SUBMITTED FOR PUBLIC
 RECORD ARE TO BE SIGNED SEALED ORIGINALS
 FAC61G15-23.002.
  
 (SECOND REVIEW) THE SCHEDULE GIVES
 DESIGN PRESSURES OF -13.5 AND -14.1, BUT
 -45 IS CIRCLED ON SHEET 9 OF THE PRODUCT
 APPROVAL.DESIGN PRESSURES ARE TO BE
 DETERMINED BY FBC TABLE 1609.6B AND
 1609.6D.
  
 (THIRD REVIEW) A NEW SCHEDULE GIVES THE
 WORST CASE PRESSURE AS -54.5 BUT PAGE 9
 HAS -45 CIRCLED.NO ANCHORING IS
 SPECIFIED ON EITHER THE INSTALLATION
 SCHEDULE OR ON THE TABLES ON THE PRODUCT
 APPROVALS.
  
 3.)ADDRESSED.
  
 4.)COMPLETE THE ATTACHED INSTALLATION
 SCHEDULE, OR PROVIDE REQUIRED
 INFORMATION IN A SIMILAR FORMAT.SEE
 ATTACHED POLICY.
  
 (SECOND REVIEW) THE FORM WAS NOT FILLED
 OUT CORRECTLY (ALL COLUMNS BLANKEXCEPT
 FOR DPS WHICH ARE INCORRECT).NO ANCHOR
 SPACING INDICATED ON PRODUCT APPROVAL.
 NOT ENOUGH INFORMATION PROVIDED TO
 DETERMINE CODE COMPLIANCE.
  
 (THIRD REVIEW) SAME PAPERWORK SUBMITTED.
 NO ANCHORING SPECIFIED.
  
 NEW COMMENT:
  
 5.)ONLY ONE PRODUCT APPROVAL WAS
 SUBMITTED. SUBMIT TWO COPIES OF ALL
 DOCUMENTS FOR PERMITTING.