Plan Review Notes For Permit 05100903 |
Permit Number |
05100903 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2005-12-10 00:00:00 | PAUL SCHMITZ | | FBC 2004 FUEL GAS CODE, PLAN REVIEW | | DENIED | | 1. SHT P-1 GAS RISER | | SHOW LOCATION OF GAS WATER HEATER. | | 2.KITCHEN STOVE,PROVIDE MANFACTURE | | INFORMATION FOR RESIDENTAL USE. | | 3. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | 4. TYPE OF GAS, (LP OR NATURAL) | | 5. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. | | 5. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | |
|