Plan Review Notes
Plan Review Notes For Permit 05100083
Permit Number 05100083
Review Stop B
Sequence Number 1
Notes
Date Text
2005-11-28 00:00:00DENIED
  
 1) SUBMIT A DRAINAGE PLAN SHOWING
 COMPLIANCE WITH 2004 FBC R401.3.
  
 2) THE ORIGINAL WET SIGNATURE OF THE
 TRUSS ENGINEER IS REQUIRED ON THE TRUSS
 LAYOUT AND TRUSS DRAWINGS. SEE F.A.C.
 61G1-16.003
  
 3) THE TRUSS LAYOUT IS REQUIRED TO BE
 REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD FOR THE STRUCTURE.
  
 4) THE PRODUCT APPROVALS REQUIRED BY
 RULE 9B-72 ARE REQUIRED TO BE REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD
 FOR THE STRUCTURE BY SECTION 106.3.3 OF
 THE CITY AMENDMENTS TO THE 2004 FBC.
  
 5) SUBMIT AN INSTALLATION SCHEDULE FOR
 THE STORM PANELS. SPECIFY THE ANCHORS
 THAT WILL BE USED, THE ANCHOR SPACING,
 THE MOUNT TYPE (SECTION # FROM PRODUCT
 APPROVAL) AND EDGE DISTANCE. THE PLANS
 SPECIFY TAPCONS WITH AN EDGE DISTANCE OF
 3". THE PRODUCT APPROVAL SPECIFIES
 3-1/2" EDGE DISTANCE. THE INFORMATION ON
 THE PLANS MUST CORRESPOND WITH THE
 INSTALLATION SELECTED FROM THE PRODUCT
 APPROVAL.
  
 6) THE NOAS SUBMITTED FOR THE SH
 WINDOWS, WINDOW MULLIONS AND GAF
 SHINGLES HAVE BEEN UPDATED FOR THE 2004
 FBC ON THE STATE WEBSITE. SUBMIT THE
 NOAS THAT ARE LISTED ON THE WEBSITE FOR
 THE PRODUCT. SEE WWW.FLORIDABUILDING.ORG
  
 7) THE INSTALLATION INSTRUCTIONS THAT
 WERE SUBMITTED FOR THE THERMA-TRU DOORS
 ARE MIAMI-DADE NOAS AND THE EVALUATION
 ENTITY SUBMITTED FOR STATE APPROVAL WAS
 NAMI. SUBMIT THE CORRESPONDING REPORTS.
 SEE FL 5262 AND THE CORRESPONDING PDF
 FILES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714