2006-09-06 00:00:00 | BUILDING PLAN REVIEW |
| ******PROVISO******* |
| ROBERT BROWN(561) 805 6652 |
| E-MAIL: [email protected] |
| |
| -PROVISO- |
| SUBMIT STRUCTURAL MULLION SHOP DRAWINGS |
| FOR ALL STOREFRONT OVER 144" TALL.THE |
| SUBMITTED ARCH ALUMINUM SERIES L-300 |
| IMPACT WALL STOREFRONT PRODUCT NOA# |
| 01-0619.01 STATES A MAXIMUM UNIT HEIGHT |
| OF 144". THIS IS NOT SUFFICIENT TO COVER |
| THE SIZE OF STOREFRONT SPECIFIED ON |
| SHEETS A-4.1 AND A-4.2 OF THE PLANS. |
| PER THE 8/25/06 MEETING WITH GLASS |
| ENGINEERING INC., STRUCTURAL MULLIONS |
| WILL BE INCORPORATED AND SHEETS A-4.1 |
| AND A-4.2 WILL BE AMENDED TO REFLECT |
| THIS AND CALL FOR SHOP DRAWINGS 'BY |
| OTHERS' TO BE SUBMITTED FOR REVIEW. |
| |
| -PROVISO- |
| SUBMIT ONE-TIME PRODUCT APPROVAL FOR |
| SLIDING GLASS DOORS.DOOR SCHEDULE |
| SHEET A-4.1 SHOWS A PROPOSED SLIDING |
| GLASS DOOR HEIGHT OF 10'-0". PER THE |
| 8/25/06 MEETING WITH GLASS ENGINEERING |
| INC., THEY WILL BE APPLYING FOR A ONE |
| TIME PRODUCT APPROVAL FOR THE 10'-0" |
| DOOR AND WILL PROVIDE THREE COPIES OF |
| THE APPROVAL.ONE-TIME APPROVAL WAS |
| PREVIOUSLY GRANTED FOR A DIFFERENT |
| PROJECT. |
| |
| -PROVISO- |
| SUBMIT ONE-TIME PRODUCT APPROVAL FOR |
| SINGLE HUNG WINDOW.WINDOW SCHEDULE |
| SHEET A-4.2 SHOWS SINGLE HUNG WINDOW |
| HEIGHTS UP TO 9'-4".PER THE 8/25/06 |
| MEETING WITH GLASS ENGINEERING INC., |
| THEY WILL BE APPLYING FOR A ONE TIME |
| PRODUCT APPROVAL FOR THE 9'-4" HIGH |
| WINDOW AND WILL PROVIDE THREE COPIES OF |
| THE APPROVAL.ONE-TIME APPROVAL WAS |
| PREVIOUSLY GRANTED FOR A DIFFERENT |
| PROJECT. |