2006-07-17 00:00:001. IT APPEARS THAT ON LS-3 TRAVEL
 DISTANCE ROUTES ARE TRAVELING OVER A
 PARKING SPACE WHERE A VEHICLE WOULD BE
 PARKED. THIS OCCURS IN THE VICINITY OF
 STAIR # 4. THIS ROUTE IS INDICATED FOR
 THREE DIFFERENT PLACES.
  
 2. PLEASE EXPLAIN HOW THE TWO DOORS WORK
 SINCE THEY ARE IN CLOSE PROXIMITY TO ONE
 ANOTHER ON LS-2. THE GARAGE AREA DOOR
 AND STAIR # 4 DOOR.
  
 3. SHOULD THE TWO 184 FEET TRAVEL
 DISTANCE ROUTES SHOWN ON PAGE LS-1
 TRAVEL PAST THE PUMP ROOM AND JANITORS
 CLOSET INTO THE HALLWAY TO REACH THE
 EXIT WHICH IS CLOSER.
  
 4. NO DOOR (S) SHOWN AT 58 OCCUPANT
 ARROW FROM CLUBROOM SHOWN ON LS-4.
 PLEASE ADVISE.
  
 5. PLEASE EXPLAIN IN SWINGING DOORS FROM
 THE CLUBROOM NEAR THE 33 FEET TRAVEL
 DISTANCE ROUTE. IS THIS THE CORRECT
 DIRECTION FOR THESE DOORS TO SWING.
  
 6. COULD NOT LOCATE BUILDING ADDRESS ON
 THE ELEVATIONS THAT FACE OKEECHOBEE
 BOULEVARD. INFORMATION LOCATED ON PAGE
 A-10.1. OKAY.
  
 7. IT APPEARS THAT THE PREVIOUS COMMENTS
 HAVE BEEN ADDRESSES.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER