2007-06-27 09:58:44 | BUILDING PLAN REVIEW |
| *******DENIED******* |
| ROBERT BROWN(561) 805 6652 |
| E-MAIL: [email protected] |
| |
| SUBMITTAL ON 3/30/07 FOR ROOFING PRODUCT APPROVALS AND |
| SPECS |
| |
| 1) FBC* 106.3.3ALL PRODUCT APPROVALS, SHOP DRAWINGS |
| AND CALCULATIONS SHALL BE REVIEWED BY THE DESIGNER OF |
| RECORD AND STAMPED WITH HIS/HER SHOP DRAWING REVIEW |
| STAMP PRIOR TO SUBMITTAL FOR BUILDING OFFICIAL REVIEW. |
| THERE ARE NO SHOP DRAWING REVIEW STAMPS, FROM THE |
| DESIGNER OF RECORD, ON ANY OF THE SUBMITTED DOCUMENTS. |
| |
| 2) THE SUBMITTED SANTAFE SPANISH 'S' CLAY ROOF TILE |
| PRODUCT APPROVAL NOA# 05-0921.02 IS A REVISION FROM THE |
| CLAY FOREVER, LLC ALTUSA "S" CLAY ROOF TILE PRODUCT |
| APPROVAL 05-0901.06 (FL # 5559) THAT WAS REVIEWED AND |
| STAMPED ON 9/9/06.REVISED ATTACHMENT CALCULATIONS |
| WOULD BE REQUIRED BECAUSE THE ROOF TILE REVISION WAS |
| ALSO INTRODUCED UNDER THE ROOFING SUB-PERMIT # |
| 07060198, AND THE CALCULATIONS SUBMITTED UNDER THAT |
| PERMIT NUMBER GENERATED THE FOLLOWING PLAN REVIEW |
| COMMENT: |
| FBC 1609.1WIND PRESSURES.BASED ON THE RWDI WIND |
| TUNNEL TEST REPORT, SHEET S-6.00 OF THE STRUCTURAL |
| PLANS FOR THE BUILDING (UNDER PERMIT # 05091425) SHOWS |
| NEGATIVE WINDPRESSURES RANGING FROM -70 PSF TO -150 |
| PSF.THESE DESIGN PRESSURE ARE FAR HIGHER THAN THE |
| PRESSURES ASSUMED IN THE SUBMITTED ATLANTIC & CARIBBEAN |
| ROOFING CONSULTING, LLC REPORTS 06-1274 L REV. AND |
| 06-1274 H REV. (BOTH DATED 6/5/07) FOR THE |
| DESIGN/SELECTION OF THE TILE AND ATTACHMENT FOR THE |
| LOWER AND HIGHER ROOF.SUBMIT CALCULATIONS THAT MEET |
| THE DESIGN PRESSURES ON STRUCTURAL PLAN SHEET S-6.00. |
| IT IS NOTED THAT THE ATLANTIC & CARIBBEAN ROOFING |
| CONSULTING, LLC REPORTS 06-1274 L AND 06-1274 H (BOTH |
| DATED 8/15/06, PRIOR TO REVISION) DID MEET THE REQUIRED |
| WIND PRESSURES, AND WERE CONSEQUENTLY REVIEWED AND |
| STAMPED ON 9/9/06 UNDER PERMIT # 05091425. |
| |
| 3) FLORIDA ADMINISTRATIVE CODE RULE 9B-72EITHER |
| STATEWIDE OR LOCAL (CITY OF WEST PALM BEACH) PRODUCT |
| APPROVAL IS REQUIRED.WHERE THE FLORIDA DEPARTMENT OF |
| COMMUNITY AFFAIRS (DCA) HAS ISSUED A STATEWIDE PRODUCT |
| APPROVAL FL # FOR THE PROPOSED PRODUCT, THE APPROPRIATE |
| STATEWIDE PRODUCT APPROVAL COVER SHEET SHALL BE |
| ATTACHED TO THE SUBMITTEDMIAMI-DADE NOA.FOR |
| REFERENCE, THE ATTACHED EXAMPLE STATEWIDE PRODUCT |
| APPROVAL COVER SHEET FL 644, FOR JOHNS MANVILLE |
| MODIFIED BITUMEN ROOFING SYSTEM OVER LIGHTWEIGHT |
| CONCRETE DECKS, HAS BEEN DOWNLOADED FROM THE DCA |
| WEBSITE AT: |
| WWW.FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX |
| PLEASE SUBMIT STATEWIDE COVER SHEETS FOR ALL OF THE |
| PROPOSED PRODUCTS THAT HAVE DCA PRODUCT APPROVAL. |
| |
| 4) ROOF TILE PRODUCT APPROVAL.A REVISION FEE, OF $50 |
| PLUS AN ADDITIONAL $10 FOR EACH PRODUCT APPROVAL THAT |
| IS DIFFERENT FROM THOSE THAT HAVE ALREADY BEEN |
| REVIEWED/STAMPED FOR THIS PROJECT, IS DUE.THE PRODUCT |
| APPROVALS SHALL BE BROUGHT BACK AS A REVISION, NOT A |
| (ZERO FEE) SUBMITTAL. |
| |
| **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| |
| END OF REVIEW COMMENTS |
| THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: |
| (561) 805 6652ROBERT BROWN |