Plan Review Notes
Plan Review Notes For Permit 05091394
Permit Number 05091394
Review Stop B
Sequence Number 1
Notes
Date Text
2005-10-31 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05091394
 ADD: 1801 S FLAGLER DR # 1209
 CONT: AAA ALUMINUM DOORS & WINDOWS
 TEL: (561)533-9869
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 *** BOTH SEETS OF ENGINEERING MUST BE
 SIGNED & SEALED BY THE ENGINEER OF
 RECORD.61G15-23.002 / 471.025(1)
  
 2)THE MIAMI-DADE REPORT SUBMITTED, PGT
 SLIDING GLASS DOOR REPORT WILL REQUIRE
 THE CONTRACTOR TO SELECT AND HIGHLIGHT
 WHICH GLASS TYPE WILL BE INSTALLED,
 PANEL WIDTH AND HEIGHT WITH THE
 ASSOCIATED POSITIVE & NEGATIVE PRESSURE.
  
 3) THE FLORIDA COVERSHEET FL 239-R2 TIES
 TO A MIAMI-DADE REPORT, SHEET 2 OF THE
 FL REPORT LIST (6) MIAMI NOAS THAT ARE
 ASSOCIATED WITH THE COVER SHEET BUT NONE
 WERE SUBMITTED. A FENESTRATION TESTING
 REPORT WAS SUBMITTED.
 EITHER SUBMIT THE MIAMI NOA THAT
 TIES TO THE FLORIDA COVERSHEET OR SUBMIT
 THE FENESTRATION REPORT FOR LOCAL
 PRODUCT APPROVAL WITH THE REQUIRED THIRD
 PARTY QUALITY ASSURANCE ENTITY LISTED
 WITH THE STATE.
 WITHOUT THE PROPER REPORTS THE DESIGN
 PRESSURES CAN NOT BE DETERMINED, ONCE
 THE CORRECT PRODUCT APPROVAL ARE
 SUBMITTED THEY WILL BE REVIEWED FOR CODE
 COMPLIANCE.
  
 4) THE SAME HOLDS TRUE FOR MULLIONS, NO
 REPORT (NOA) WAS SUBMITTED, ONLY THE FL
 COVERSHEET.
 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved