2005-11-07 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 05091291 |
| ADD:317 3RD WY |
| CONT: MASTERCARE SHUTTERS |
| TEL: (561)262-1212 |
| BLD CODE= 2001 FLORIDA BUILDING CODE * |
| WEST PALM BEACH AMENDMENTS |
| |
| 1STREVIEW |
| ACTION: DENIED |
| |
| PLANS DO NOT INDICATE HOW OCCUPANTS |
| SHALL BE ABLE TO ESCAPE WHEN SHUTTERS |
| ARE INSTALLED. |
| 1005.4.5 SECURITY AND HURRICANE |
| PROTECTION DEVICES. BARS, GRILLES, |
| GRATES OR SIMILAR SECURITY DEVICES |
| SHALL BE PERMITTED PROVIDED THE |
| MINIMUM SIZE AND OPERATIONAL |
| CONSTRAINTS OF SUCH DEVICES ARE IN |
| ACCORDANCE WITH ?1005.4.2, ?1005.4.3, |
| AND ?1005.4.4.THE TEMPORARY |
| INSTALLATION OR CLOSURE OF STORM |
| SHUTTERS, PANELS, AND OTHER APPROVED |
| HURRICANE PROTECTION DEVICES SHALL BE |
| PERMITTED ON EMERGENCY ESCAPE AND |
| RESCUE OPENINGS IN GROUP R OCCUPANCIES |
| DURING THE THREAT OF A STORM. |
| SUCH DEVICES SHALL NOT BE REQUIRED TO |
| COMPLY WITH THE OPERATIONAL |
| CONSTRAINTS OF ?1005.4.2, ?1005.4.3 |
| AND ?1005.4.4.WHILE SUCH PROTECTION |
| IS PROVIDED, AT LEAST ONE MEANS OF |
| ESCAPE FROM THE DWELLING OR DWELLING |
| UNIT SHALL BE PROVIDED.THE MEANS OF |
| ESCAPE SHALL BE WITHIN THE FIRST |
| FLOOR OF THE DWELLING OR DWELLING UNIT |
| AND SHALL NOT BE LOCATED WITHIN A |
| GARAGE.OCCUPANTS IN ANY PART OF THE |
| DWELLING OR DWELLING UNIT SHALL BE |
| ABLE TO ACCESS THE MEANS OF ESCAPE |
| WITHOUT PASSING THROUGH A LOCKABLE |
| DOOR NOT UNDER THEIR CONTROL. |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |