2006-05-16 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 SECOND REVIEW OF REVISION TO REDUCE
 HEIGHT OF ENTRY DOORS, AND SUBMITTAL FOR
 ALTERNATIVE STORM PANEL SHUTTERS TO
 ADDRESS PROVISO.
  
 5) THIS COMMENT WAS NOT ADDRESSED FROM
 THE PREVIOUS REVIEW.ARCHITECTURAL PLAN
 SHEET A-4.1 AND MODULAR BUILDING PLAN
 SHEET 7 OF 7, SHOW DOOR AND WINDOW BUCKS
 OF 1"X 4" P.T.WOOD, SCREWED TO THE METAL
 FRAMESTRUCTURE.SHEET A-4.1 SHOULD BE
 REVISED TO SHOW HOW THE SHUTTERS WILL BE
 ANCHORED, IN ACCORDANCE WITH THE PRODUCT
 APPROVAL, TO THE STEEL FRAME STRUCTURE.
 ALSO, THE SAME COMMENT ALSO APPLIES TO
 ANCHORING OF THE STOREFRONT PER THE
 SUBMITTED ARCH ALUMINUM PRODUCT
 APPROVAL.PROVIDE THE REQUIRED
 ADDITIONAL DETAILS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS