2005-10-17 00:00:00 | BUILDING REVIEW CHECKLIST: |
| 1- CONTRACTOR'S LICENSE IS FOR ALUMINUM |
| SPECIALTIES. WINDOW INSTALLTION IS OUT |
| OF THE SCOPE OF WORK FOR THIS LICENSE. |
| NEED CONTRACTOR WITH GLASS AND GLAZING |
| LICENSE TO APPLY FOR THIS PERMIT. |
| |
| 2- BEDROOM WINDOWS NEED TO COMPLY WITH |
| MIN. SIZE AS REQUIRED BYSEC. 1005.4.4 |
| FBC 2001. MIN. SIZE IS 24" CLEAR OPENING |
| HEIGHT, 20" CLEAR OPENING WIDTH AND |
| 5.7S.F. MIN. CLEAR OPENING. CLEARLY |
| IDENTIFY ON KEY PLAN BEDROOM WINDOWS AND |
| REVISE WINDOW SIZE AS REQUIRED TO COMPLY |
| WITH CITED SEC. ABOVE. |
| |
| 3- DADE COUNTY NOA SUBMITTED IS NOT THE |
| SAME THAT WAS SUBMITTED FOR FLORIDA |
| PRODUCT APPROVAL. NEED NOA #03-0514.01 |
| AND MAKE SURE THAT COPIES ARE LEGIBLE. |
| |
| 4- PROVIDE FLORIDA OR LOCAL PRODUCT |
| APPROVAL FOR: |
| A) WINDOW MULLIONS. |
| B) IMPACT WINDOWS WITH FROSTED GLASS AS |
| SPECIFIED FOR BATHROOMS. |
| |
| 5- DESIGN PRESSURES CHART IS NOT |
| LEGIBLE. NEED A CLEAR ONE. |
| |
| 6- NEED RECORDED NOTICE OF COMMENCEMENT. |
| |
| 7- THERE ARE 2 BUILDINGS IN THIS |
| PROPERTY. SPECIFY WHICH BUILDING IS THE |
| ONE HAVING THE WINDOWS REPLACED. |
| |
| JULIO GOMEZ |
| BUILDING PLANS EXAMINER |
| (561)805-6712. |