Date |
Text |
2006-02-28 00:00:00 | PAUL SCHMITZ |
| [email protected] |
| FBC2001 FUEL GAS CODEPLAN REVIEW |
| FBC 2001 PLUMBING CODEPLAN REVIEW FBC |
| 2001 FL ACESSIBILITY CODE PLANREVIEW |
| DENIED |
| |
| PREVIOUS NOTE #2 NOT ADDRESSED. |
| |
| 104.2 DRAWINGS AND SPECIFICATIONS. |
| 104.2.1 REQUIREMENTS. AS REQUIRED BY |
| 104.3.1.1 OF THE CODE, TWO OR MORE |
| COPIES OF |
| SPECIFICATIONS, AND OF DRAWINGS DRAWN TO |
| SCALE WITH SUFFICIENT CLARITY AND DETAIL |
| TO INDICATE THE |
| NATURE AND CHARACTER OF THE WORK, SHALL |
| ACCOMPANY THE APPLICATION FOR A PERMIT. |
| SUCH |
| DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF |
| NOTES OR OTHERWISE, AS TO |
| THE QUALITY OF MATERIALS, WHERE QUALITY |
| IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. |
| SUCH INFORMATION SHALL BE SPECIFIC, AND |
| THE TECHNICAL CODES SHALL NOT BE CITED |
| AS A WHOLE OR IN |
| PART, NOR SHALL THE TERM ?LEGAL? OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR |
| SPECIFIC INFORMATION. |
| ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA |
| SHALL BEAR THE NAME AND |
| SIGNATURE OF THE PERSON RESPONSIBLE FOR |
| THE DESIGN. |
| |
| 2)SHT A-1 BREAK ROOM SINKS: |
| 11-4.24 SINKS. |
| ?11-4.24.1 GENERAL. SINKS REQUIRED TO |
| BE ACCESSIBLE BY ?11-4.1 SHALL |
| COMPLY WITH ?11-4.24. |
| ?11-4.24.2 HEIGHT. SINKS SHALL BE |
| MOUNTED WITH THE COUNTER OR RIM NO |
| HIGHER THAN 34 IN. (865 MM) ABOVE THE |
| FINISH FLOOR. |
| ?11-4.24.3 KNEE CLEARANCE. KNEE |
| CLEARANCE THAT IS AT LEAST 27 IN. (685 |
| MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 |
| IN (485 MM) DEEP SHALL BE |
| PROVIDED UNDERNEATH SINKS. |
| ?11-4.24.4 DEPTH. EACH SINK SHALL BE A |
| MAXIMUM OF 6-1/2 IN (165 MM) DEEP. |
| ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR |
| FLOOR SPACE AT LEAST 30 IN. BY 48 |
| IN. (760 MM BY 1220 MM) COMPLYING WITH |
| 11-4.2.4 SHALL BE PROVIDED IN |
| FRONT OF A SINK TO ALLOW FORWARD |
| APPROACH.THE CLEAR FLOOR SPACE SHALL |
| BE ON AN ACCESSIBLE ROUTE AND SHALL |
| EXTEND A MAXIMUM OF 19 IN. (485 MM) |
| UNDERNEATH THE SINK (SEE FIGURE 11-32) |
| ?11-4.24.6 EXPOSED PIPES AND SURFACES. |
| HOT WATER AND DRAIN PIPES EXPOSED |
| UNDER SINKS SHALL BE INSULATED OR |
| OTHERWISE CONFIGURED SO AS TO PROTECT |
| AGAINST CONTACT.THERE SHALL BE NO |
| SHARP OR ABRASIVE SURFACES UNDER SINKS. |
| ?11-4.24.7 FAUCETS. FAUCETS SHALL |
| COMPLY WITH ?11-4.27.4.LEVER- |
| OPERATED, PUSH-TYPE, TOUCH-TYPE, OR |
| ELECTRONICALLY CONTROLLED MECHANISMS |
| ARE ACCEPTABLE DESIGNS. |
| END OF COMMENTS, QUESTIONS. |