2005-09-27 00:00:00 | 1) FBC 1606.1.7WIND LOAD.THE PLANS |
| SHALL STATE THE BASIC WIND SPEED, WIND |
| IMPORTANCE FACTOR, WIND EXPOSURE |
| CATEGORY, INTERNAL PRESSURE COEFFICIENT, |
| AND EXTERIOR COMPONENT AND CLADDING |
| DESIGN WIND PRESSURES.ADD THIS |
| INFORMATION TO THE PLANS. |
| |
| 2) FBC. 1507.4.2.2 DECL SLOPE. CLAY AND |
| CONCRETE ROOF TILE SHALL BE INSTALLED ON |
| ROOF SLOPES OF 2 1/2 :12 OR GRATER. ALSO |
| SEE FBC 1507.4.3.1FOR MIMIMUM |
| UNDERLAYMENT. |
| |
| 3) THE UNDERLAYMENT SHALL BE |
| MECHANICALLY FASTENED TO THE DECK. SEE |
| THE INSTALLATION OF THE PRODUCT |
| APPROVAL. (4.1). |
| |
| 4) DUE TO THE STRUCTURE OF THIS PROJECT |
| THE CONSTRUCTION DOCUMENTS SHALL |
| ILLUSTRATE,DESCRIBE,AND DELINEATE THE |
| TYPE OF ROOFING SUSTEM,MATERIALS, |
| FASTENINGS REQUIREMENTS, WIND RESISTANCE |
| RATING THAT ARE REQUIRED TO BE |
| INSTALLED.SEE WPB AMENDEMENTS104.2.1.1. |
| |
| 5)THE ATTATCHMENT FOR THESIMPSON |
| "HUS26-2" IS FOR WOOD CONSTRUCTION, |
| HOWEVER, THE PLANS SHOWS IT CONNECTING |
| TO CONCRETE.CHOOSE A CONCRETE HANGER |
| WHICH IS APPROPRIATE FOR THE CONNECTION. |
| |
| 6) THE PRODUCT APPROVAL NEEDS THE STATE |
| COVER SHEETS. PRODUCT APPROVALS |
| SUBMITTED WITH PERMIT APPLICATION AFTER |
| OCTOBER 1, 2003 ARE REQUIRED TO COMPLY |
| WITH THE FLORIDA PRODUCT APPROVAL |
| SYSTEM. FOR INFORMATION PLEASE SEE THE |
| STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG. |
| |
| |