2005-11-12 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 CHAPTER 1 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| 1. SHT A001 INDEX SHEET. ALL SHEETS ON |
| INDEX SHEET NOT SUBMITTED. PLEASE SUBMIT |
| ALL SHEETS. PLANS NOT COMPLETE. SECTION |
| 104.2.1. |
| 2. SHTS I-1 & I-2 INFORMATION REQUIRED |
| ON IMPRESSION SEAL OF LANDSCAPE |
| ARCHITECT IS NOT IMPRESSED ON THE PLANS. |
| PLEASE RESEAL SHEETS. FAC 61G1-16.002(1) |
| AND FS 481.321 |
| 3. SHT A101 URINAL REQUIRED IN THE MENS |
| TOILET ROOM FOR THE SWIMMING POOL PER |
| TABLE 424.1.6.1. |
| 4. SHT A101 TOILET ROOMS SHALL COMPLY |
| WITH SECTIONS 11-4.16, 11-4.18, 11-4.19, |
| AND 11-4.22 AND ALL SUBSECTIONS. PLEASE |
| PROVIDE A DETAIL SHOWING ALL |
| REQUIREMENTS. |
| 5. SHT A102 TOILET ROOM FOR GUARD HOUSE |
| TO COMPLY WITH SECTIONS 11-4.16, |
| 11-4.19, AND 11-4.22 WITH ALL |
| SUBSECTIONS. PLEASE PROVIDE A DETAIL |
| SHOWING ALL REQUIREMENTS. |
| 6. SUBMIT A SANITARY & A WATER RISER |
| DIAGRAM FOR THE GUARD HOUSE. SHOW ALL |
| PIPE SIZES, TRAPS, VENTS ECT. FOR THE |
| SANT. SHOW ALL PIPE SIZES, VALVES, AND, |
| IF REQUIRED, WATER HAMMER ARRESTORS PER |
| SECTION 604.9. |
| 7. PLUMBING PLANS FOR SWIMMING POOL |
| TOILET ROOMS WERE NOT SUBMITTED. PLEASE |
| SUBMIT THE PLUMBING PLANS ALONG WITH THE |
| SANT. AND WATER RISER DIAGRAMS. SECTIONS |
| 104.2.1 & 104.3.1.1. |
| |