Plan Review Notes
Plan Review Notes For Permit 05080290
Permit Number 05080290
Review Stop P
Sequence Number 3
Notes
Date Text
2006-04-05 00:00:00PROVISO;
  
 SPECIFICATION "A" APPLIES TO ALL
 BATHROOMS AND THE FIXTURES IN THOSE
 BATHROOMS MUST BE USABLE. IF A LAVATORY
 IS INSTALLED WHERE SPACE DOES NOT PERMIT
 A CLOSE PARALLEL APPROACH WITH THE 30" X
 48" CLEAR FLOOR SPACE CENTERED ON THE
 BASIN, THE CENTEWR LINE OF THE BASIN
 MUST BE AT LEAST 15" FROM AN ADJOINING
 WALL OR FIXTURE. IT MUST HAVE KNEE SPACE
 AT LEAST 30" WIDE TO ALLOW A USER TO
 EXECUTE A FORWARD APPROACH INTO CLEAR
 FLOOR SPACE REQUIRED. PAGE 7.49 THE TOP
 OF ALL VANITY CABINETS SHALL BE 34"
 MAXIMUM. PAGE 7.52