2005-12-14 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 CHAPTER 1 |
| FHA-98 DESIGN MANUAL |
| |
| ***FROM PREVIOUS REVIEW*** |
| |
| 1. ALL FIRST FLOOR UNITS SHALL COMPLY |
| WITH REQUIREMENTS 1 THRU 7 OF THE FAIR |
| HOUSING ACT DESIGN MANUAL. PLEASE SUBMIT |
| A DETAIL SHOWING COMPLIANCE WITH ALL |
| REQUIREMENTS. INDICATE SPECIFICATION "A" |
| OR "B" AS REQUIRED ON PAGE 7.34. THE |
| CLEAR FLOOR SPACE FOR ALL USABLE |
| FIXTURES SHALL BE APPLIED OR |
| SUPERIMPOSED OVER THE FLOOR PLAN. FOR |
| THE W/C SEE PAGE 7.43. - CLEAR FLOOR |
| SPACE FOR THE W/C'S NOT SHOWN. |
| 4. SHTS P2 OF 2 ALL UNITS WATER HEATER |
| DETAIL. P/T DISCHARGE LINE SHALL NOT |
| HAVE ANY TRAPED SECTIONS. SECTION |
| 504.7.1. (SEE WATER HEATER NOTES). |
| ****************NEW COMMENT************* |
| 1B. WATER HEATER PANS ON THE FIRST FLOOR |
| ARE NOT REQUIRED. IF INSTALLED, THE |
| ELEVATION ABOVE GRADE FOR THE PAN SHALL |
| BE INDICATED SO AS TO INSURE THE PAN |
| WILL DRAIN AS THE TERMINATION OF THE PAN |
| DRAIN IS SHOWN AS 6" ABOVE GRADE. |
| SECTIONS 104.2.1 & 504.8. |
| |