Date Text
2006-04-03 00:00:00PROVISO;
 SPECIFICATION "A" APPLIES TO ALL
 BATHROOMS, AND ALL FIXTURES IN THOSE
 BATHROOMS MUST BE USABLE. IF A LAVATORY
 IS INSTALLED WHERE SPACE DOES NOT PERMIT
 A CLOSE PARALLEL APPROACH WITH THE 30" X
 48" CLEAR FLOOR SPACE CENTERED ON THE
 BASIN, THE CENTER LINE OF THE BASIN MUST
 BE 15" FROM AN AJOINING WALL OR FIXTURE.
 ITMUST HAVE KNEE SPACE AT LEAST 30" WIDE
 TO ALLOW A USER TO EXECUTE A FORWARD
 APPROACH INTO CLEAR FLOOR SPACE BENEATH
 THE FIXTURE. EITHER REMOVABLE VANITY
 CABINETS OR OPEN CLEAR FLOOR SPACE
 REQUIRED. PAGE 7.49 THE TOP OF ALL
 VANITY CABINETS SHALL BE 34" MAXIMUM.
 PAGE 7.52