Date |
Text |
2005-08-12 00:00:00 | DENIED |
| |
| 1) FBC 704.2.1.4 CORRIDOR PARTITIONS, |
| SMOKE STOP PARTITIONS, HORIZONTAL EXIT |
| PARTITIONS, EXIT ENCLOSURES, AND FIRE |
| RATED WALLS REQUIRED TO HAVE PROTECTED |
| OPENINGS SHALL BE EFFECTIVELY AND |
| PERMANETLY IDENTIFIED WITH SIGNS OR |
| STENCILING IN A MANNER ACCEPTABLE TO THE |
| AUTHORITY HAVING JURISDICTION. SUCH |
| IDENTIFICATION SHALL BE ABOVE ANY |
| DECORATIVE CEILING CEILING AND IN |
| CONCEALED SPACES. SUGGESTED WORDING" |
| FIRE & SMOKE BARRIER PROTECT ALL |
| OPENINGS". |
| |
| 2) FBC 1004.1.2 EVERY ROOM OR TENANT |
| SPACE SHALL BE PROVIDED WITH A MINIMUM |
| OF ONE MEANS OF EGRESS.EVERY ROOM OR |
| TENANT SPACE WHICH HAS AN OCCUPANT |
| LOAD OF 50 OR MORE PERSONS OR IN WHICH |
| THE TRAVEL DISTANCE FROM THE MOST |
| REMOTE POINT TO THE ENTRANCE TO THE |
| EXIT ACCESS FROM THE ROOM OR TENANT |
| SPACE EXCEEDS 75 FT (23 M) SHALL HAVE |
| NOT LESS THAN TWO EGRESS DOORS. |
| |
| 3) FBC 1004.1.4 WHERE 2 OR MORE EXITS OR |
| EXIT ACCESS DOORS ARE REQUIED, AT LEAST |
| 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL |
| BE PLACED A DISTANCE APART EQUAL TO NOT |
| LESS THAN 1/2 OF THE LENGTH OF THE MAX- |
| IMUM OVERALL DIAGONAL DIMENSION OF THE |
| BUILDING OR AREA TO BE SERVED. |
| EXCEPTIONS: |
| 2. IN BUILDINGS PROTECTED THROUGHOUT BY |
| AN APPROVED AUTOMATIC SPRINKLER SYSTEM, |
| THE MINIMUM SEPARATION DISTANCE BETWEEN |
| TWO EXITS OR EXIT ACCESS DOORS SHALL BE |
| AT LEAST 1/3 THE LENGTH OF THE MAXIMUM |
| OVERALL DIAGONAL DIMENSION OF THE |
| BUILDING OR AREA TO BE SERVED. |
| |
| 4) IDENTIFY THE AREAS ADJACENT TO THE |
| PROJECT AREA. INDICATE EXIT CORRIDORS, |
| LOCATION OF EXIT STAIRWYS, ETC. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| |
| |
| |