Plan Review Notes For Permit 05080084
Permit Number 05080084
Review Stop P
Sequence Number 3
Notes
Date Text
2006-04-04 00:00:00PROVISO;
  
 SPECIFICATION "A" APPLIES TO ALL
 BATHROOMS, AND ALL FIXTURES IN THOSE
 BATHROOMS MUST COMPLY. IF A LAVATORY IS
 INSTALLED WHERE SPACE DOES NOT PERMIT A
 CLOSE PARALLEL APPROACH WITH THE 30" X
 48" CLEAR FLOOR SPACE CENTERED ON THE
 BASIN, THE CENTER LINE OF THE BASIN MUST
 BE AT LEAST 15" FROM AN ADJOINING WALL
 OR FIXTURE. IT MUST HAVE KNEE SPACE AT
 LEAST 30" WIDE TO ALLOW A USER TO
 EXECUTE A FORWARD APPROACH INTO CLEAR
 FLOOR SPACE BENEATH THE FIXTURE. EITHER
 REMOVABLE VANITY CABINETS OR OPEN CLEAR
 FLOOR SPACE REQUIRED. PAGE 7.49 THE TOP
 OF ALL VANITY CABINETS SHALL BE 34"
 MAXIMUM. PAGE 7.52