Notes
Date Text
2005-08-06 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05071214
 ADD: 2770 WILDNERNESS RD
 CONT: SEARS HOME IMPROVEMENT
 TEL: (954)590-2203
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 **********REVISED FOR ONE STORY BUILDING
 OKJ WITMER 8-10-05********
  
  
 1ST REVIEW
 ACTION: DENIED
  
 1005.4.1 EVERY SLEEPING ROOM LOCATED ON
 THE FIRST, SECOND AND THIRD
 STORY OR WITHIN BASEMENTS OF GROUP R
 OCCUPANCIES SHALL HAVE AT LEAST ONE
 EXTERIOR EMERGENCY ESCAPE AND RESCUE
 OPENING.THE EMERGENCY ESCAPE AND
 RESCUE OPENING SHALL BE PERMITTED TO
 OPEN INTO A SCREEN ENCLOSURE, OPEN
 TO THE ATMOSPHERE, WHERE A SCREEN DOOR
 IS PROVIDED LEADING AWAY FROM THE
 RESIDENCE.
  
 1005.4.4 MINIMUM SIZE. THE MINIMUM NET
 CLEAR OPENING HEIGHT DIMENSION
 SHALL BE 24 INCHES (610 MM).THE
 MINIMUM NET CLEAR OPENING WIDTH
 DIMENSION SHALL BE 20 INCHES (508 MM).
 THE MINIMUM NET CLEAR OPENING
 AREA SHALL BE 5.7 SQ FT (0.53 M^2).
  
 EXCEPTION: GROUND FLOOR OPENINGS
 SHALL BE PERMITTED TO HAVE A MINIMUM
 NET CLEAR OPENING OF 5.0 SQ FT (0.47
 M^2).
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026