Date |
Text |
2005-08-08 00:00:00 | DENIED; |
| 1) FBC-2001 SEC 424.2.6.1 ENGINEERING |
| DESIGN, CONSTRUCTION AND WORKMANSHIP. |
| ANSI/NSPI-5. (ADD TO NOTES) |
| 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE |
| WITH ANSI/ASME A112.19.8M. PROVIDE MODEL |
| NUMBER AND MANUF INFO FOR VAC LOCK. |
| (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) |
| |
| 3) FBC-2001424.2.6.6.5 WHERE PROVIDED, |
| THE VACUUM OR PRESSURE CLEANER FITTING |
| SHALL BE LOCATED AT LEAST 6" AND NOT |
| GREATER THAN 12" BELOW THE MINIMUM OPER- |
| ATING WATER LEVEL OR AS AN ATTACHMENT TO |
| THE SKIMMER. |
| 4) FBC-2001 424.2.8.1 VALVES SHALL BE |
| MADE OF MATERIALS THAT ARE APPROVED IN |
| THE FLA BLDG CODE, PLUMBING.THEY WILL |
| BE READILY ACCESSIBLE FOR MAINT. AND |
| REMOVAL.SEC 424.2.8.2 FULL WAY VALVES |
| SHALL BE INSTALLED TO INSURE PROPER |
| FUNCTION OF THE FILTRATION AND PIPING |
| SYSTEMS.SEC 424.2.8.3 WHERE CHECK |
| VALVES ARE INSTALLED THEY SHALL BE OF |
| THE SWING OR VERTICAL CHECK PATTERNS. |
| SEC 424.2.8.4 COMBINATION VALVES SHALL |
| REQUIRE APPROVAL OF THE ADMINISTRATIVE |
| AUTHORITY PRIOR TO THEIR INSTALLATION. |
| 5) FBC-2001 424.2.12.1 PRESSURE TESTS. |
| PER MANUFACTURE RECOMMENDATIONS, NO AIR |
| TEST SHALL BE APPROVED FOR PVC PIPE AND |
| FITTINGS. (ADD TO NOTES) |
| 6)424.2.9 WATER SUPPLY, LOCAL ORD. # |
| 2853-95, BACKFLOW REQUIRED ON WATER |
| SERVICE. (ADD TO NOTES) |
| 7)424.2.13.2 JOINTS AND CONNECTIONS, FBC |
| PLUMBING SEC. 605.21, PURPLE PRIMER ON |
| PVC PIPING. (ADD TO NOTES) |
| PLUMBING PLAN REVIEW BY; |
| JOHN LEECH |
| 805-6695 |
| |
| |
| |