Date Text
2006-07-28 00:00:001) THE BUILDING FOOTPRINT AND POOL DECK
 DOES NOT MATCH THOSE APPROVED BY ORD.
 NO. 3804-04.A MINOR AMENDMENT APPROVAL
 IS REQUIRED FOR THE NEW LAYOUT.
  
 2) PARKING DETAILS FOR REGULAR, COMPACT
 AND DISABLED SPACES AT ALL ANGLES ARE
 REQUIRED.WHEEL STOPS ARE TO BE TWO
 FEET FROM THE END OF THE SPACE TO THE
 EDGE OF THE WHEEL STOP PER CITY ZONING
 REGULATIONS.PARKING SPACES SHALL BE
 STRIPED FOR THE ENTIRE DEPTH OF THE
 PARKING SPACE.THIS NEEDS TO BE
 CORRECTED NOT ONLY ON THE DETAIL BUT
 ALSO THE PARKING SPACE SHEETS.
  
 3) SPACES 1-037, 1-038 AND 1-039 ON
 SHEET A 1.02 P2; 2-037, 2-038 AND 2-040
 (ANGLED) ON SHEET A 1.03 P2; AND 3-037,
 3-038 AND 3-039 ON SHEET A 1.04 P2 DO
 NOT HAVE THE WHEEL STOPS IN THE CORRECT
 LOCATIONS (REPEAT COMMENT).THE ANGLE
 SHALL BE STATED ON THE PLANS AND PARKING
 DETAIL.
  
 4) ALL AREAS BETWEEN SUPPORT COLUMNS
 THAT ARE NOT PARKING SPACES (TOO NARROW)
 SHALL BE MARKED AS ?NO PARKING.?
  
 5) SPACE 2-039 LABELED AS 2-040.SPACES
 ON THE RAMPS MISLABELED. TWO SPACE
 3-133, NO SPACE 3-139.SPACES 3-044 TO
 3-050 IN MIDDLE AISLE ARE MISLABELED.
  
 6) VERIFY THE TURNING RADIUS WORKS FOR
 SUVS ON LEVELS 2 AND 3 IN THE NORTHEAST
 CORNER OF THE GARAGE.
  
 7) PARKING COUNT CHART ON SHEET A0.02
 SHALL BREAK DOWN THE SMALL SPACES ON
 EACH LEVEL AND PER THE PARKING DIRECTOR
 THE VALET SPACES (NOTE - NOT ALL VALET
 SPACES MAY BE SMALL SPACES).THE
 PARKING COUNTS ARE INCORRECT.SEE
 BELOW:
  
 A) THE SMALL SPACE MARKED AS 1-076 MAY
 NOT BE COUNTED AS A SPACE OF ANY KIND AS
 IT HAS SUPPORT COLUMNS ON EITHER SIDE OF
 THE SPACE ENTRANCE WITHOUT SUFFICIENT
 WIDTH TO FUNCTIONALLY USE.THIS REDUCES
 THE PROVIDED PARKING BY 1 SPACE - 204 +
 2 HC ON 1ST LEVEL.
  
 B) THERE ARE NO SPACES 2-066 AND 2-067,
 AND SPACE 2-050 DOES NOT HAVE ADEQUATE
 BACK OUT AREA.HC SPACES 201 AND 202
 ARE NOT SHOWN AT THE REQUIRED 12 FEET
 WIDTH. THIS REDUCES THE PROVIDED PARKING
 BY 3 SPACES AND 2 HC SPACES - 154 + 2 HC
 ON 2ND LEVEL.
  
 C) HC SPACES 301 AND 302 ARE NOT SHOWN
 AT THE REQUIRED 12 FEET WIDTH. THIS
 REDUCES THE PROVIDED PARKING BY 2 HC
 SPACES - 2 HC ON 3RD LEVEL.
  
 D) ONLY 153 PARKING SPACES ARE PROVIDED
 ON THE 3RD LEVEL, NOT 161 AS STATED.
  
 8) TOTAL PARKING PROVIDED IN THE GARAGE
 IS 605 SPACES (UNKNOWN ON-STREET
 PARKING).OF THESE 74 ARE SMALL SPACES
 AND 6 SPACES ARE HANDICAP SPACES.THE
 ADDENDUM SHEET TO ORD. NO. 3804-04,
 SECTION 6, STATES THAT THERE ARE 704
 PARKING SPACES REQUIRED.CHANGING
 (LOWERING) THE AMOUNT OF REQUIRED
 PARKING MAY ONLY BE APPROVED BY THE CITY
 COMMISSION THROUGH THE MAJOR AMENDMENT
 PROCESS.
  
 9) THE REQUIRED PARKING SHALL BE
 CALCULATED USING THE FORMULA APPROVED BY
 ORD. NO. 3804-04, NOT THE INCORRECT
 FORMULA INCLUDED ON SHEET A0.02.
 10) WHAT ARE THE SPACES LISTED AS 1-S01,
 1-S02 AND 1-S03 ON SHEET A 1.02?WHY
 ARE THESE NOT INCLUDED IN THE PARKING
 COUNTS?THESE NEED TO SHOW MORE DETAILS
 (SPACE SIZE AND ANGLE AND DRIVE AISLE
 WIDTH).
  
 11) ADJUST THE CURBING BY THE PARALLEL
 SPACES BY THE WEST ENTRANCE ISLAND TO
 HAVE 45 DEGREE ANGLES FOR EASIER PARKING
 (REPEAT COMMENT).THE ENDS OF THE
 OUTSIDE SPACES SHOULD HAVE THE 45 DEGREE
 ANGLE, LIKE THE PARKING SPACES
 ON-STREET.
  
 12) PROVIDE A PLAN SHOWING THE
 DIMENSIONS AND COUNTS OF THE PROPOSED
 ON-STREET PARKING SPACES.ADDITIONALLY,
 PROVIDE A LETTER FROM THE CITY?S
 ENGINEERING AND PARKING DEPARTMENTS
 APPROVING THE SIZE AND LOCATION OF THE
 SPACES, INCLUDING ANY HANDICAP SPACE
 REQUIRED AND PROVIDED.
  
 14) PER THE CONSTRUCTION SERVICES
 DEPARTMENT, THERE NEED TO BE HANDICAP
 PARKING SPACES PROVIDED THAT MAY BE SELF
 PARKED.
  
 15) THE ENTRY GATE ON 23RD STREET HAS
 BEEN MOVED TO SHORTEN THE STACKING
 DISTANCE FROM WHAT WAS APPROVED IN ORD.
 NO. 3804-04.EITHER REVISE THE BUILDING
 PERMIT PLANS OR A MINOR AMENDMENT
 APPROVAL IS REQUIRED.
  
 16) NO CIVIL AND LANDSCAPE PLANS
 INCLUDED TO REVIEW.ANY CHANGES TO THE
 LANDSCAPE PLAN FROM ORD. NO. 3804-04
 WOULD REQUIRE MINOR AMENDMENT APPROVAL.
  
 17) SIGN ON PLANS DOES NOT MATCH
 APPROVED SIGN FROM ORD. NO. 3804-04.
 MINOR AMENDMENT APPROVAL REQUIRED.
  
 18) A CHART SHOWING THE UNIT BREAKDOWN
 IS REQUIRED.
  
 19) WHY ARE ONLY THE 14 TOWNHOUSE TYPE
 UNITS AND NOT THE 5 LIVE WORK UNITS
 EXCLUDED FROM THE FHA HANDICAP PARKING
 REQUIREMENTS?
  
 20) PLEASE NOTE THAT IF A MAJOR
 AMENDMENT IS PURSUED, THEN THE MINOR
 AMENDMENT ITEMS WILL BE INCLUDED WITH
 THE MAJOR AMENDMENT.
  
 CONTACT ERIC SCHNEIDER @ 822-1435.
2006-07-24 00:00:00NOTES FORTHCOMING.
  
 CONTACT ERIC SCHNEIDER (561) 822-1435.