Date |
Text |
2006-07-29 00:00:00 | DENIED |
| REFERENCE: FBC-2001 PLUMBING |
| FBC-2001 FUEL GAS |
| FBC-2001 CHAPTER 1 |
| FBC-2001 CHAPTER 11 |
| FBC-2001 BUILDING |
| FHA-98 DESIGN MANUAL |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| COMMENTS FROM PREVIOUS REVIEWS: |
| |
| **************************************** |
| A. COMMENTS FROM PREVIOUS REVIEW: NO |
| COMMENT RESPONSES TO REVIEW WERE NOT |
| SUBMITTED. COMMENT NUMBERS SHALL REMAIN |
| THE SAME AS FIRST REVIEW UNTIL ADDRESSED |
| **************************************** |
| |
| 1. OK |
| 2. OK |
| 3. OK |
| 4. OK |
| |
| 5. SHTS L-1, L4, AND IR-1 THRU IR-5, NO |
| INFORMATION ON THE SEAL HAS BEEN |
| IMPRESSED ON THE SHEETS AS REQUIRED BY |
| FAC 61G1-16.001. ALSO THE CERTIFICATE OF |
| AUTHORIZATION NUMBER AND THE PRINTED |
| NAME OF THE PERSON SEALING THE DOCUMENT |
| SHALL APPEAR ON THE TITLE BLOCK PER FAC |
| 61G1-16.004(2) & (6) AND FS 481.219, |
| 481.2055.(NO RESPONSE, SHEETS NOT |
| RESUBMITTED. PLEASE CLARIFY) |
| ****RESPONSE NOTED, BUT PRINTED NAME OF |
| THE PERSON SEALING THE DOCUMENT AND CA# |
| STILL NOT INDICATED. SEE ATTACHED SHEET |
| FROM DBPR WEBSITE. |
| |
| 6. OK |
| 7. OK |
| 8. OK |
| 9. OK |
| 10. OK |
| 11. OK |
| |
| 12. SHT A4.01 TYPICAL UNIT 'AN' SHOW |
| BACKING & OPENING DIMENSIONS FOR THE W/C |
| OPENINGS FOR ADDITIONAL BATHROOMS PER |
| BATHROOM REQUIREMENTS PAGE 7.35. THIS |
| WILL BE REQUIRED FOR SHT A4.02 UNIT 'AS' |
| SHT A4.03 UNIT 'BS', SHT A4.04 UNIT |
| 'BSM', SHT A4.05 UNIT 'CN', SHT A4.06 |
| UNIT 'CNM', A4.07 UNIT 'CS', SHT A4.15 |
| UNIT 'FS2', A4.16 UNIT 'GN', SHT A4.20 |
| UNIT 'KN', SHT A4.22 UNIT 'LS', SHT |
| A4.23 UNIT 'MN1', SHT A4.24 UNIT 'MN2', |
| SHT A4.25 UNIT 'MNM', SHT A4.26 UNIT |
| 'MS1', SHT A4.27 UNIT 'MS2', SHT 4.28 |
| UNIT 'MSM', SHT A4.29.1 UNIT 'NS', SHT |
| A4.30.1 UNIT 'PS', SHT A4.31.1 UNIT |
| 'QN', SHT A4.32 UNIT 'RN', SHT A4.33 |
| UNIT 'RS', SHT A4.34 UNIT 'SN', SHT |
| A4.35 UNIT 'SNM', SHT A4.36 UNIT 'TS', |
| SHT A4.37 UNIT 'TSM', UNIT A4.41.1 UNIT |
| 'LTN', SHT A4.42.1 UNIT 'LTS', & SHT |
| A4.31.1 UNIT 'STSM'. (NO RESPONSE, NOT |
| ADDRESSED. ADDITIONAL BATHROOMS IN THE |
| UNIT ARE EXEMPT -ONLY- FROM MANEUVERING |
| AND CLEAR FLOOR SPACE REQUIREMENTS AT |
| FIXTURES) |
| ****RESPONSE NOTED, BUT DIMENSIONS SHALL |
| BE SHOWN IN EACH UNIT, OR INDICATE IN |
| EACH UNIT WHERE THE DIMENSIONS SHALL BE |
| LOCATED. |
| |
| 13.OK |
| 14. NOT USED |
| 15. NOT USED |
| |
| 16. SHTS A4.38, A4.39, & A4.40 ENTRY |
| LEVEL TO BE COVERED PER FHA. SUBMIT |
| DETAILS FOR BATHROOMS. (RESPONSE NOTED, |
| BUT THE FIRST FLOOR SHALL HAVE A |
| ACCESSIBLE PATH TO THE ELEVATORS). |
| |
| 17. GROUND FLOOR CONFERENCE ROOM SINKS |
| SHALL BE ACCESSIBLE. SUBMIT A DETAIL |
| SHOWING COMPLIANCE WITH SECTION 11-4.24 |
| AND ALL SUBSECTIONS. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT THE FOLLOWING |
| INFORMATION SHALL BE SHOWN: |
| A. 11-4.24.5 CLEAR FLOOR SPACE, CABINET |
| DOORS SHALL BE REMOVED, NO DOORS IN THE |
| CLEAR FLOOR SPACE. |
| B. 11-4.24.6 EXPOSED PIPES & SURFACES |
| C. 11-4.24.7 FAUCETS |
| 18. OK |
| 19. OK |
| 20. NOT USED |
| 21. THE FOLLOWING INFORMATION IS |
| REQUIRED FOR GAS PERMIT: |
| |
| C. SUBMIT A DETAIL SHOWING THE TYPE, |
| LOCATION, SIZE AND TERMINATION OF THE |
| GAS VENTS PER FBC-2001 FUEL GAS CODE |
| SECS. 502 THRU 506. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT INDICATE WHERE |
| THE DETAIL CAN BE LOCATED. |
| |
| D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS |
| EQUIPMENT TO VERIFY COMPLIANCE WITH |
| STANDARDS NFPA 54, NFPA 58, AND THE |
| FBC-2001 FUEL GAS CODE SEC 402.2. (NO |
| RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE POOL/SPA |
| HEATER SHEETS HAVE NOT BEEN FOUND. |
| |
| E. (NEW COMMENT) PIPE SIZE INCORRECT AT |
| LAST SPA HEATER. 1-1/4" REQUIRED. 1-1/2" |
| REQUIRED FOR 2 SPA HEATERS. 2" REQUIRED |
| FOR 3 SPA HEATERS. |
| |
| 22.(INFORMATIONAL) |
| |
| 23. ALL FLOOR PLAN SHEETS, SHOW THE |
| LOCATION & NUMBER OF EACH RISER THRU THE |
| BUILDING ON EACH FLOOR PLAN AND EACH |
| LEVEL. SECTION 104.2.1. (NO RESPONSE, |
| NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE RISERS ARE |
| ONLY SHOWN ON THE GROUND FLOOR. WHERE IS |
| LEVEL 3? |
| |
| 24.OK |
| |
| 25. SHT P-2 SHOW THE PIPING FOR ALL |
| TRENCH DRAINS WITH PIPE SIZES. THIS |
| SHALL BE REFLECTED ON THE STORM RISER |
| DIAGRAM. SECTION 104.3.1.1. (NO |
| RESPONSE, NOT ADDRESSED FOR TRENCH DRAIN |
| AT COL. LINE G/01). |
| ****RESPONSE NOTED, BUT PIPING NOT SHOWN |
| ON P-2 OR P-68 |
| |
| 26. GREASE INTERCEPTOR SHALL BE SIZED BY |
| THE ENVIRONMENTAL COMPLIANCE MANAGER. |
| WASTE ORD. #3434. PLEASE CONTACT LYNN |
| MASSON AT (561) 822-2271, FAX (561) |
| 822-2279 OR E-MAIL [email protected]. (NO |
| RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT APPROVAL |
| REQUIRED BY LYNN MASSON FOR LOCATION AND |
| MAINTENANCE. |
| |
| 27. SHT P-4 RAIN WATER LEADERS, SHOW ALL |
| PIPE SIZES. RECALCULATE ADDITION ON SOME |
| RWL'S, INDICATE RWL RISER NUMBERS, 3" |
| OVERFLOW SHOWN CONNECTING TO PRIMARY |
| SYSTEM AT COL. 24 BETWEEN COLS, A&B. |
| PLEASE CLARIFY. SECTION 104.2.1. -(SHOW |
| ALL SECONDARY ROOF DRAINS, WITH PIPE |
| SIZES, SF, ETC.). (NO RESPONSE NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, ADDITION STILL NOT |
| CORRECT IN SOME PLACES. RECHECK ALL |
| ADDITION OF THE SQUARE FOOTAGE AS IT |
| ACCUMULATES IN THE SYSTEM. - RWL'S ARE |
| NOT NUMBERED. THIS IS REQUIRED TO TRACK |
| THE RISERS THRU THE BUILDING. - |
| SECONDARY DRAINS ON THE 5TH FLOOR ARE |
| SHOWN IN THE PLANTERS FOR SOME, AND IN |
| OPEN AREAS FOR OTHERS. PLEASE CLARIFY. |
| |
| 28. OK |
| 29. OK |
| 30. OK |
| |
| 31. SHT P-7 SANT. PIPING NOT ALLOWED IN |
| THE EGRESS STAIRWAY. NFPA-101 SECTION |
| 7.1.3.2.1(6). (NO RESPONSE, NOT |
| ADDRESSED).RESPONSE NOTED, BUT THE |
| PIPING SHALL BE POURED IN SOLID |
| CONCRETE, OR DRAIN SHALL BE DESIGNED FOR |
| THE VOID. |
| |
| 32. OK |
| 33. OK |
| 34. OK |
| 35. SHT P-9 THE FOLLOWINGPIPING |
| LAYOUTS DO NOT REFLECT RISER DIAGRAMS |
| 44, 47, 42, 40, 39, 20, & 4. SECTION |
| 104.2.1. (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT RISER #4 STILL |
| DOES NOT REFLECT THE FLOOR PLAN. |
| |
| 36. SHT P-13 PIPING FOR THE DWV AND |
| STORM SYSTEMS NOT APPROVED IN EGRESS |
| STAIRWAYS. NFPA-101 SECTION 7.1.3.2.1(6) |
| AND SECTION 1006.1.3.1. (METHOD OF |
| ADDRESSING NOT APPROVED. SEE BUILDING |
| PLAN REVIEW COMMENT #38). |
| ****RESPONSE NOTED, BUT THE PIPING WILL |
| HAVE TO BE IN A SOLID POUR, OR A DRAIN |
| FOR THE VOID WILL BE REQUIRED. |
| |
| 37. P-14. CONDENSATE IS INDICATED AS 5' |
| SEPARATION FOR THE SUPPORTS. INDICATE |
| MATERIAL FOR CONDENSATE PIPING. IF PVC, |
| MAXIMUM 4' SEPARATION OF SUPPORTS PER |
| TABLE 305.5. SUBMIT A DETAIL SHOWING |
| COMPLIANCE WITH 140 MPH WIND LOAD FOR |
| SUPPORTS. (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT S RESIDENTIAL |
| TOWER ROOF LEVEL, NO DETAIL INDICATED. |
| |
| 38. SHT P-15 PIPING OFFSETS NOT SHOWN ON |
| RISER DIAGRAM 56, 59A, 92, 93, 94, 95, |
| 96, 97, 98, 99, & 100. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT RISER 94 DOES |
| NOT REFLECT THE FIXTURE/WALL LAYOUT. |
| (SEE SHT P-17 ALSO). |
| |
| 39. SHT P-15 PIPING NOT APPROVED IN |
| EGRESS STAIRWAYS. NFPA-101 SECTION |
| 7.1.3.2.1(6). (METHOD OF ADDRESSING NOT |
| APPROVED. SEE BUILDING PLAN REVIEW #38). |
| ****RESPONSE NOTED, BUT THE PIPING SHALL |
| BE IN SOLID POUR OR A DRAIN SHALL BE |
| INSTALLED FOR THE VOID. |
| |
| 41. OK |
| 42. OK |
| 43. OK |
| |
| 44. SHT P-17 THE FOLLOWING RISERS DO NOT |
| REFLECT PIPING LAYOUT: 50, 51, 52, & 55. |
| SECTION 104.2.1. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT 50 & 52 DOES NOT |
| REFLECT THE FLOOR PLAN AND 52 SHOWS AN |
| OFFSET ON SHT P-16. |
| |
| 46. OK |
| |
| 48. SHT P-22 CONDENSATE LINE SHOWN AS 5' |
| SEPARATION BETWEEN SUPPORTS. INDICATE |
| TYPE OF MATERIAL. IF PVC PER TABLE 305.5 |
| MAXIMUM 4' SEPARATION BETWEEN SUPPORTS. |
| SUBMIT A DETAIL FOR SUPPORTS SHOWING HOW |
| THEY ARE ATTACHED TO THE ROOF AND SHOW |
| COMPLIANCE WITH 140 MPH WIND LOAD. (NO |
| RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT NO DETAIL |
| LOCATED. |
| 49. OK |
| |
| 50. SHT P-23 RECREATION AT LEVEL 4 |
| PIPING DOES NOT REFLECT THE FIXTURE |
| LAYOUT. PLEASE CORRELATE FIXTURE LAYOUT |
| WITH PIPING LAYOUT. SECTION 104.2.1. |
| (RISER DIAGRAM DOES NOT REFLECT FIXTURE |
| LAYOUT EITHER).(W/C MISSING ON RISER |
| DIAGRAM). |
| ****RESPONSE NOTED, BUT THE W/C IS STILL |
| MISSING AT LEVEL 4 RECREATION. |
| |
| 51. OK |
| 52. OK |
| 53. OK |
| 54. OK |
| 55. OK |
| 56. OK |
| 57. SHT P-53 RISER 8 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SECTION 914.1. |
| (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT RELIEF VENT |
| STILL SHOWN AFTER 11 BRANCH INTERVALS. |
| 58. OK |
| 59. OK |
| |
| 60. SHT P-54 RISER 14 LOWER OFFSET VENT |
| REQUIRED. SEC. 915.3 - MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. |
| (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE LOWER OFFSET |
| VENT SHALL CONNECT BETWEEN THE OFFSET & |
| THE NEXT LOWER HORIZONTAL BRANCH. 915.3 |
| |
| 62. SHT P-55 RISER 20 BATHROOM SHOWN ON |
| 4TH FLOOR ON FLOOR PLAN, BUT SHOWN ON |
| 5TH FLOOR ON RISER. CORRELATE RISER AND |
| FLOOR PLAN. SEC. 104.2.1. - W/M FOR 16TH |
| FLOOR NOT SHOWN ON RISER. SEC. 104.2.1. |
| (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE BATHROOM IS |
| STILL SHOWN ON THE 5TH FLOOR. |
| |
| 63. OK |
| |
| 64. SHT P-55 RISER 23 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1 - |
| LOWER OFFSET VENT REQD. SEC. 915.3. (NO |
| RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE LOWER OFFSET |
| VENT SHALL CONNECT BETWEEN THE OFFSET |
| AND THE NEXT LOWER BRANCH. SECTION |
| 915.3. |
| |
| 65. OK |
| |
| 66. SHT P-56 RISER 26 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. - |
| NO BRANCH CONNECTIONS ON HORIZONTAL |
| OFFSET. SEC. 711.2. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT THE LOWER OFFSET |
| VENT SHALL CONNECT BETWEEN THE OFFSET |
| AND THE NEXT LOWER BRANCH. SECTION |
| 915.3. |
| |
| 67. SHT P-56 RISER 28 NO HORIZONTAL DRY |
| VENTS. SEC. 905.3/905.4 (16TH FLOOR). |
| ****NOT ADDRESSED. |
| |
| 68. SHT P-56 RISER 29 LOWER OFFSET VENT |
| REQD. SEC 915.3. - NO CONNECTION TO |
| HORIZONTAL OFFSET. SEC. 711.2. (NO |
| RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE LOWER OFFSET |
| VENT SHALL CONNECT BETWEEN THE OFFSET |
| AND THE NEXT LOWER BRANCH. 915.3. |
| |
| 69. SHT P-56 RISER 30 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. - |
| NO HORIZONTAL DRY VENTS. SEC. |
| 905.3/905.4. (NO RESP0NSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT OFFSETS IN THE |
| STACK VENT SHALL BE ABOVE THE FLOOD |
| LEVEL OF THE HIGHEST FIXTURE. 905.4. |
| |
| 70. SHT P-56 RISER 32 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1 - |
| NO HORIZONTAL DRY VENTS. SEC. |
| 905.3/905.4. - UPPER OFFSET VENT REQD. |
| SEC. 915.2. - SEPARATE RISER SECTION AT |
| BASE OF STACK FOR POWDER ROOM, INDICATE |
| RISERS CONNECTING FROM UPSTREAM. (33, |
| 37, 37A) SEC. 104.2.1. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT THE LOWER OFFSET |
| VENT SHALL CONNECT BETWEEN THE OFFSET |
| AND THE NEXT LOWER BRANCH. 915.3. |
| |
| 71. SHT P-56 RISER 33 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. - |
| NO HORIZONTAL DRY VENT. SEC. 905.3/905.4 |
| - DOES NOT REFLECT FLOOR PLAN @ 4TH |
| LEVEL. (BASE OF STACK) SEC. 104.2.1. - |
| VENT FROM 1ST FLOOR FLOOR DRAIN NOT |
| SHOWN ON RISER. (SEE P-3, P-4, P-67). |
| (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE VENT SHALL |
| OFFSET ABOVE THE FLOOD LEVEL OF THE |
| HIGHEST FIXTURE. 905.4. |
| 72. OK |
| 73. OK |
| 74. OK |
| |
| 75. SHT P-59 RISER 50 DOES NOT REFLECT |
| THE FLOOR PLAN 4TH LEVEL. SEC. 104.2.1. |
| (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT RISER STILL DOES |
| NOT REFLECT THE FLOOR PLAN. |
| |
| 76. OK |
| |
| 77. SHT P-59 RISER 52 DOES NOT REFLECT |
| FLOOR PLAN LEVEL 2. - UPPER OFFSET VENT |
| REQUIRED. SEC. 915.2. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT OFFSET IS SHOWN |
| ON P-15, BUT NOT ON THE RISER. |
| |
| 78. OK |
| |
| 79. SHT P-60 RISER 56 DOES NOT REFLECT |
| THE FLOOR PLAN 3RD LEVEL. - OFFSET VENTS |
| REQD. SECS. 915.2/915.3. - MAX. 10 |
| BRANCH INTERVALS TO RELIEF VENT. SEC. |
| 914.1. - NO CONNECTIONS TO HORIZONTAL |
| OFFSET. SEC. 711.2.- NO HORIZONTAL DRY |
| VENTS. SECS. 905.3/905.4. (NO RESPONSE, |
| NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT VENT OFFSET |
| SHALL BE ABOVE THE FLOOD LEVEL OF THE |
| HIGHEST FIXTURE. 905.4. |
| |
| 80. OK |
| 81. OK |
| 82. OK |
| 83. OK |
| 84. OK |
| |
| 85. SHT P-61 RISERS 63, 64 DO NOT |
| REFLECT THE FLOOR PLAN. PLEASE CLARIFY |
| SEC. 104.2.1. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT RISERS STILL DO |
| NOT REFLECT THE FLOOR PLAN. |
| |
| 86. SHT P-61 RISER 67 MAX 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. - |
| NO HORIZONTAL DRY VENTS. SECS. 905.3 |
| 905.4. (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE VENT SHALL |
| OFFSET ABOVE THE FLOOD LEVEL OF THE |
| HIGHEST FIXTURE. 905.4. |
| |
| 87. OK |
| 89. OK |
| |
| 90. SHT P-62 RISER 71 MAX. 10 BRANCH |
| INTERVALS TO RELIEF VENT. SEC. 914.1. - |
| NO DRY HORIZONTAL VENT. SECS. 905.3 |
| 905.4. (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT THE VENT OFFSET |
| SHALL BE ABOVE THE FLOOD LEVEL OF THE |
| HIGHEST FIXTURE. 905.4. |
| |
| 91. OK |
| |
| 92. SHT P-62 RISER 73 & 74 MAX. 10 |
| BRANCH INTERVALS TO RELIEF VENT. SEC. |
| 914.1. (NO RESPONSE, NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT RISER 73 SHOWS |
| THE RELIEF VENT AFTER 11 BRANCH |
| INTERVALS. |
| |
| 94. OK |
| 95. OK |
| 96. OK |
| |
| 97. SHT P-64 RISERS 89,94,95,99,101,102 |
| & 103 DO NOT REFLECT THE FLOOR PLANS. |
| SECTION 104.2.1. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT RISER 94 STILL |
| DOES NOT REFLECT THE FLOOR PLAN. |
| |
| 98. OK |
| |
| 99. SHT P-67 FOLLOWING ARE CORRECTIONS |
| TO BE MADE TO SANT. |
| - RISERS 23 & 23A MISLABELED. |
| - 2" VENT UP TO RISER |
| 67 TO READ "TO RISER 67A". (SEE RISER |
| 67A). - "2" VENT FOR CONT. SEE P-53" |
| INDICATE RISER VENT WILL CONNECT TO. - |
| - THIS SHEET SHOWS LEVELS AS PARK, |
| PARK 2, PARK 3 ECT., BUT SHEETS P-15, |
| P-16. & P-17 SHOWS LEVELS AS GROUND |
| FLOOR, PARTIAL N. RES. LOFTS, N. LOFTS |
| MEZZ. ECT. PLEASE CLARIFY & CORRELATE |
| SHEET LEVELS. - RECHECK ADDITION OF |
| FIXTURE UNITS AS THEY ACCUMULATE IN THE |
| SYSTEM. SOME FIXTURES UNITS ARE NOT |
| SHOWN AND ADDED TO THE SYSTEM. INDICATE |
| THE SLOPE OF THE PIPE WHERE THE FIXTURES |
| UNITS ARE MORE THAN ALLOWED FOR MINIMUM |
| SLOPE. ALL PIPE IN A GIVEN RUN SHALL BE |
| INSTALLED IN A UNIFORM SLOPE AS REQUIRED |
| IN SECTION 704.1. INDICATE ON PLANS. |
| SECTION 104.2.1. (NO RESPONSE, NOT |
| ADDRESSED). |
| ****RESPONSE NOTED, BUT RISERS 23 & 23A |
| ARE STILL MISLABELED. (SHOULD NOW BE 23, |
| 23A, 21, NOT 23, 234. - RISER NOT |
| INDICATED FOR VENT. - LEVELS STILL |
| DIFFERENT FROM SHEET TO SHEET. CLARIFY. |
| - STILL MISSING PIPE SIZE, AND NEED TO |
| SHOW DFU'S AS THEY ACCUMULATE IN THE |
| SYSTEM. ADDITION TO BE CHECKED AS IT IS |
| NOT CORRECT IN SOME AREAS. - CHECK |
| PROPER APPLICATION TO THE FIXTURE UNIT |
| TABLES 709.1, 709.2, (FOR TRAPS LARGER |
| THAN INDICATED IN 709.1), 710.1(1), |
| 710.1(2). - CONFLICTS IN SLOPE, SHOWS |
| 1/16"/FT IN SOME AREAS, BUT NOTE STATES |
| "1/8"/FT FOR ALL PIPE 3" & LARGER. |
| PLEASE CORRELATE. |
| |
| 100. SHT P-68 HORIZONTAL STORM RISER |
| DOES NOT REFLECT STORM PIPING IN |
| BUILDING. STRUCTURES S1 THRU S9 NOT |
| SHOWN. - NO ROOF DRAINS 2650SF, 2350SF, |
| 2450SF ECT. FOUND. - NO EXFILTRATION |
| TRENCHES FOUND. - NO TRENCH DRAINS |
| FOUND, RISERS SHOWS 25TH, 26TH, 27TH |
| FLOORS ECT. - NO POINT OF REFERENCE TO |
| FLOOR PLAN CAN BE FOUND. - RISER HARD TO |
| READ, PLEASE INCREASE THE SIZE OF THE |
| STORM RISER DIAGRAM AND POSSIBLY SPLIT |
| UP TO TWO PAGES TO MAKE RISER EASIER TO |
| READ. SECTION 104.2.1.3. (NO RESPONSE, |
| NOT ADDRESSED). |
| ****RESPONSE NOTED, BUT ADDITION ON |
| RISER DIAGRAM AND FLOOR NEEDS TO BE |
| RECHECKED. SOME INCONSISTANCIES. ALSO |
| SOME AREAS OF THE RISER DIAGRAM DOES NOT |
| REFLECT THE FLOOR PLAN. PLEASE CHECK |
| ENTIRE RISER DIAGRAM. |
| |
| 101. OK |
| 102. OK |
| 103. OK |
| |
| 104. BACKFLOW PROTECTION REQUIRED FOR |
| IRRIGATION, POOLS, TRASH CHUTE WASH |
| DOWNS, AND COOLING TOWER MAKE UP WATER. |
| SECTION 608. INDICATE METHOD OF |
| PROTECTION FOR EACH SYSTEM. (NO |
| RESPONSE, NOT ADDRESSED. |
| ****RESPONSE NOTED, BUT NO PROTECTION |
| INDICATED FOR THE IRRIGATION, NOR FOR |
| THE POOL MAKE UP WATER. |
| |
| 105. PLANS ARE INCOMPLETE AT THIS TIME |
| AND MORE COMMENTS MAY BE FORTHCOMING |
| WITH THE NEXT REVIEW. |
| ****PLANS STILL DO NOT SEEM TO BE 100% |
| **************************************** |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| (NO RESPONSE) |
| ****RESPONSE NOTED, BUT ON SOME COMMENTS |
| WITH MULTIPLE COMMENTS, NOT ALL SECTIONS |
| OF THE COMMENT WERE ADDRESSED IN |
| RESPONSE. ALSO RSPONSES WERE NOT |
| DETAILED AS TO WHERE THE CORRECTION |
| COULD BE FOUND. |
| **************************************** |
| **************************************** |
| |
| NEW COMMENTS: (2ND REVIEW) |
| |
| 1B. OK |
| |
| 2B. SHOW PIPING FOR FIXTURES IN THE |
| SHEET WITH FIXTURES, NOT ON THE FLOOR |
| BELOW. THIS IS CONFUSING AND IS HARD TO |
| FOLLOW THE PIPING, FIXTURES, AND RISER |
| DIAGRAM ISOMETRICS. SECTION 104.2.1. |
| ****RESPONSE NOTED, BUT THIS IS NOT |
| ACCEPTABLE. THE PIPING AS SHOWN IS STILL |
| CONFUSING. SOME PIPING THAT SHOULD BE ON |
| THE SAME FLOOR AS THE FIXTURES, (SUCH AS |
| WASH MACHINE PIPING, LAV AND KITCHEN ARM |
| PIPING, ETC.), IS SHOWN ON THE FLOOR |
| BELOW ALSO. ALL PIPING SHALL BE SHOWN ON |
| THE SAME FLOOR AS THE FIXTURES. |
| |
| 3B. BUILDING PLANS SHALL BE DRAWN TO |
| MINIMUM OF 1/8" SCALE. SECTION |
| 104.2.1.3. ( SEE SHEETS P-2 THRU P-6. |
| PLEASE SUBMIT 1/8" SCALE FOR THESE |
| SHEETS FOR REVIEW). |
| ****RESPONSE NOTED, BUT SHT P-6 HAS NOT |
| BEEN CHANGED. |
| |
| 4B. OK |
| |
| 5B. SHT P-1A LOCATED BETWEEN P-19 & |
| P-20. INDEX CALLS FOR IT TO BE PRIOR TO |
| SHT P-1. PLEASE CORRELATE SHEETS & |
| INDEX. SHT 104.2.1. |
| ****RESPONSE NOTED, BUT SHT P-1A IS |
| INSERTED AFTER P-1. CORRELATE THE INDEX |
| AND SHEETS. |
| |
| **************************************** |
| **************************************** |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| PLANS FOR COMPAIRSON. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUM- BER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICA TION PAGE WHERE THE CHANGES |
| CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| **************************************** |
| **************************************** |
| |
| NEW COMMENTS: (3RD REVIEW) |
| |
| 1C. SHT P-1 PIPE SIZES FOR THE SPA |
| HEATERS ARE INCORRECT. 2" REQUIRED FOR 3 |
| HEATERS, 1-1/2" REQUIRED FOR 2 HEATERS, |
| AHD 1-1/4" REQUIRED FOR THE LAST HEATER. |
| TABLE 402.2 |
| |
| 2C. SHTS P-2, P-2A, P-2B, P-2C, P-2D AND |
| RISER DIAGRAM P-68, P-68A, P-68B, P-68C. |
| CHECK THE ADDITION OF SQUARE FOOTAGE IN |
| SYSTEM. ALSO MAKE SURE THE RISER DIAGRAM |
| REFLECT THE FLOOR PLAN THROUGHOUT. |
| SECTION 104.2.1, TABLE 1106.2, 1106.3 |
| |
| 3C. SHT P-7 DOWNSTREAM OF RISER 24, 24A |
| DOES NOT REFLECT THE FLOOR PLAN. SECTION |
| 104.2.1. |
| |
| 4C. ALL FLOOR PLAN SHEETS. NO PIPING IS |
| SHOWN FOR WASH MACHINE DRAINS. (SEE |
| RISER 32 FOR EXAMPLE). SECTION 104.2.1. |
| |
| 5C. SHT P-9 UNITS 'LT2' EITHER SIDE OF |
| COL. LINE S.06 SHOW NO LAV FIXTURES. |
| SECTION 104.2.1. |
| |
| 6C. SHT P-9 RISERS 16 & 22 OFFSETS SHOWN |
| ARE NOT SHOWN ON THE RISER DIAGRAMS. - |
| SHOW PIPING TO W/C'S AND LAVS. SECTION |
| 104.2.1. |
| |
| 7C. SHT P-15 RISER 73,75,76,77,78,79 |
| DFU'S DO NOT REFLECT DFU'F INDICATED ON |
| THE RISER DIAGRAM. CORRELATE DFU'S. |
| SECTION 104.2.1. |
| |
| 8C. SHT P-16 RISER 52 OFFSET NOT SHOWN |
| ON THE RISER. CORRELATE FLOOR PLAN AND |
| RISER DIAGRAM. SECTION 104.2.1. |
| |
| 9C. SHT P-17 RISERS 62 & 94 FLOOR PLANS |
| DO NOT REFLECT THE RISER DIAGRAMS. |
| |
| 10C. SHT P-17 FLOOR PLAN INDICATED |
| PARTIAL SOUTH NORTH RESIDENTIAL LOFTS |
| 2ND LEVEL, BUT SHEET TITLE SHOWS NORTH |
| RESIDENTIAL LOFTS 2ND LEVEL. PLEASE |
| CORRELATE SHEET INFORMATION. 104.2.1. |
| |
| 11C. SHT P-19 FLOOR PLAN INDICATES NORTH |
| RESIDENTIAL, BUT SHEET TITLE INDICATES |
| SOUTH RESIDENTIAL. CORRELATE. 104.2.1. |
| |
| 12C. SHT P-23 RECREATION AT LEVEL 2 |
| SHOWS TWO WASTE ARMS FOR ONE LAV. PLEASE |
| CLARIFY. SECTION 104.2.1. |
| |
| 13C. SHT P-37 MISLABELED AS P-39. |
| 104.2.1. |
| |
| 14C. SHT P-52 RISER DIAGRAM FOR 1W UNIT, |
| W/C FOR POWDER NOT VENTED. SECTION |
| 901.2.1. |
| |
| 15C. SHT P-53 STACK DIAGRAM #4 DOES NOT |
| REFLECT THE FLOOR PLAN AT LEVEL 4. |
| PLEASE CORRELATE. 104.2.1. |
| |
| 16C. SHT P-54 STACK RISER #12 SHOWS A |
| SHOWER, BUT FLOOR PLAN SHOWS A TUB. |
| PLEASE CORRELATE. 104.2.1. |
| |
| 17C.SHT P-54 STACK RISER #16 CHECK |
| VENTING LEVEL 2. SECTION 104.2.1. |
| |
| 18C. SHT P-54 STACK RISER #18 INDICATES |
| AN EXTRA BRANCH LINE BETWEEN LEVELS 3 & |
| 4. MORE INFORMATION REQUIRED. PLEASE |
| EXPLAIN WHAT THIS CONNECTS TO. SECTION |
| 104.2.1. |
| |
| 19C. SHT P-55 STACK RISER #24 HORIZONTAL |
| BRANCH LINE SHALL NOT CONNECT TO THE |
| HORIZONTAL STACK OFFSET. 711.2 (2 |
| INSTANCES). |
| |
| 20C. SHT P-55 STACK RISER #23 HORIZONTAL |
| BRANCH LINE SHALL NOT CONNECT TO THE |
| HORIZONTAL STACK OFFSET. 711.2 (2 |
| INSTANCES LEVEL 3 & LEVEL 4). |
| |
| 21C. SHT P-56 STACK RISER #29 DOES NOT |
| REFLECT THE FLOOR PLAN LEVEL 2. |
| CORRELATE. SECTION 104.2.1. |
| |
| 22C. SHT P-59 STACK RISER #50 DOES NOT |
| REFLECT THE FLOOR PLAN LEVEL 4. |
| CORRELATE. SECTION 104.2.1. |
| |
| 23C. SHT P-60 STACKS 56 & 58 HORIZONTAL |
| BRANCH LINES SHALL NOT CONNECT TO THE |
| HORIZONTAL STACK OFFSET. SECTION 711.2 |
| (2 PLACES EACH STACK). |
| |
| 24C. SHT P-61 STACK RISER #62 HORIZONTAL |
| BRANCH CONNECTIONS TO THE HORIZONTAL |
| STACK OFFSETS NOT APPROVED. 711.2 (2 |
| PLACES). |
| |
| 25C. SHT P-61 STACK RISER #63 FIXTURES |
| NOT SHOWN ON THE FLOOR PLAN TO REFLECT |
| THE RISER AT THE BOTTOM OF THE STACK. |
| PLEASE CLARIFY. SECTION 104.2.1. |
| |
| 26C. SHT P-61 STACK RISER #64 LEVEL 4 |
| OFFSET NOT SHOWN ON THE FLOOR PLAN. |
| PLEASE CORRELATE. SECTION 104.2.1. |
| |
| 27C. ALL RISERS & FLOOR PLANS WHERE |
| THERE ARE HORIZONTAL OFFSETS. HORIZONTAL |
| BRANCH CONNECTIONS SHALL NOT CONNECT |
| WITH IN 2FT OF OFFSETS. SECTION 711.2. |
| |
| 28C. SHT P-64 STACK RISER #94 DOES NOT |
| REFLECT THE FLOOR PLAN AT THE BASE OF |
| THE STACK. CORRELATE. 104.2.1. |
| |
| 29C. SHT P-67 MAXIMUM 2900 DFU'S ON 12" |
| PIPE AT 1/16"/FT SLOPE. 3538 DFU'S |
| SHOWN. NOTE INDICATED 3" OR MORE PIPE |
| SIZE SHALL SLOPE 1/8"/FT. SOUTH BLDG. |
| DRAIN SHOWS 1/16TH/FT SLOPE IN VARIOUS |
| PLACES. CORRELATE. SECTION 104.2.1 AND |
| TABLE 710.1(1) |
| |
| 30C. SHT P-67 5" MINIMUM REQUIRED |
| UPSTREAM OF RISER 102. TABLE 710.1(1). |
| PLEASE INDICATE ON RISER. |
| |
| 31C. SHT P-67 CLEANOUT MISSING UPSTREAM |
| OF THE BASE OF RISER 26/27 ETC. DOES NOT |
| REFLECT THE FLOOR PLAN. CORRELATE. |
| 104.2.1. |
| |
| 32C. SHT P-67 SHOWS RISER 23, 234. |
| SHOULD BE 23, 23A, 21. SECTION 104.2.1. |
| |
| 33C. SHT P-67 UPSTREAM OF RISER 39, 40 |
| ETC., SHOWS VENT FOR FLOOR DRAINS. |
| INDICATE WHERE VENT CONNECTS. SECTION |
| 104.2.1. |
| |
| 34. THE FOLLOWING STACKS HAVE HORIZONTAL |
| DRY VENTS AT THE TOP OF THE STACKS. |
| THESE VENTS SHALL BE OFFSET ABOVE THE |
| FLOOD LEVEL OF THE HIGHEST FIXTURES. |
| THESE STACKS ARE ON SHEETS P-53, P-54K, |
| P-55, P-56, P-59, P-60, AND P-62. - |
| STACK NUMBERS 1, 2, 13, 15, 10, 12, 14, |
| 16, 18, 20, 22, 23, 26, 28, 30, 32, 33, |
| 48, 48A, 53, 55, 56, 57, 60, 67, 71, 73, |
| 74. SECTION 905.4. |
| |
| 35C. SHT P-39 NO PIPING SHOWN ON THE |
| FLOOR PLAN 2ND FLOOR LOFT UNITS. SHOW |
| PIPING. SECTION 104.2.1. |
| |
| 36C. ALL RISERS WITH OFFSET VENTS. LOWER |
| OFFSET VENTS SHALL CONNECT BETWEEN THE |
| OFFSET AND THE NEXT LOWER HORIZONTAL |
| BRANCH CONNECTION. SECTION 915.3. |
| |
| 37C. SHT P-62 RISER 72 NO LAV ARM SHOWN |
| ON LEVEL 4. CLARIFY. SECTION 104.2.1. |
| |
| 38C. SHT P-62 RISER 79 SHOWS WASH |
| MACHINE PIPING FOR 2ND LEVEL, BUT NO |
| WASH MACHINE SHOWN. CLARIFY. 104.2.1. |
| |
| 39C. INDICATE THE LOCATION FOR THE VENTS |
| FOR THE CONDENSATE RISERS. VENTS ARE NOT |
| ALLOWED IN THE WALLS, OR IN THE A/C ROOM |
| IF THE ROOM IS A PLENUM. SECTION |
| 104.2.1. |
| |
| **************************************** |
| **************************************** |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| PLANS FOR COMPAIRSON. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUM- BER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICA TION PAGE WHERE THE CHANGES |
| CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| **************************************** |
| **************************************** |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |