2005-07-23 00:00:00 | PLUMBING PLANREVIEW FBC 2001 DENIED. |
| PROVIDE INFORMATION ON CLOTHES DRYER |
| EXHAUST, PER THE FOLLOWING MECHANICAL |
| CODE SECTIONS, SEPERATE MECHANICAL |
| PERMIT REQUIRED. |
| |
| ?M504.4 EXHAUST INSTALLATION. DRYER |
| EXHAUST DUCTS FOR CLOTHES DRYERS |
| SHALL TERMINATE ON THE OUTSIDE OF THE |
| BUILDING AND SHALL BE EQUIPPED WITH A |
| BACKDRAFT DAMPER.SCREENS SHALL NOT BE |
| INSTALLED AT THE DUCT TERMINATION. |
| DUCTS SHALL NOT BE CONNECTED OR |
| INSTALLED WITH SHEET METAL SCREWS OR |
| OTHER |
| FASTENERS THAT WILL OBSTRUCT THE FLOW. |
| CLOTHES DRYER EXHAUST DUCTS SHALL |
| NOT BE CONNECTED TO A GAS VENT |
| CONNECTOR, GAS VENT OR CHIMNEY.CLOTHES |
| DRYER EXHAUST DUCTS SHALL NOT EXTEND |
| INTO OR THROUGH DUCTS OR PLENUMS. |
| |
| ?M504.5 MAKEUP AIR. INSTALLATIONS |
| EXHAUSTING MORE THAN 200 CFM (0.09 |
| M^3/S) SHALL BE PROVIDED WITH MAKEUP |
| AIR.WHERE A CLOSET IS DESIGNED FOR |
| THE INSTALLATION OF A CLOTHES DRYER, AN |
| OPENING HAVING AN AREA OF NOT LESS |
| THAN 100 SQUARE INCHES (0.0645 M^2) |
| SHALL BE PROVIDED IN THE CLOSET |
| ENCLOSURE. |