Date |
Text |
2005-08-06 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT:05070631 |
| ADD: 7210 WINDING BAY LN |
| CONT: NATURAL BEAUTY WOOD PRO., INC |
| |
| TEL: (561)732-0224 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: REVIEWED |
| |
| BUILDING PROVISO: |
| |
| IF FENCE IS PART OF A POOL BOUNDRY MUST |
| COMPLY WITH: |
| 424.2.17.1.1 THE TOP OF THE BARRIER |
| SHALL BE AT LEAST 48 INCHES ABOVE GRADE |
| MEASURED ON THE SIDE OF THE BARRIER |
| WHICH FACES AWAY FROM THE SWIMMING POOL. |
| THE MAXIMUM VERTICAL CLEARANCE BETWEEN |
| GRADE AND THE BOTTOM OF THE BARRIER |
| SHALL BE 2 INCHES MEASURED ON THE SIDE |
| OF THE BARRIER WHICH FACES AWAY FROM THE |
| SWIMMING POOL.WHERE THE TOP OF THE |
| POOL STRUCTURE IS ABOVE GRADE THE |
| BARRIER MAY BE AT GROUND LEVEL OR |
| MOUNTED ON TOP OF THE POOL STRUCTURE. |
| WHERE THE BARRIER IS MOUNTED ON TOP OF |
| THE POOL STRUCTURE, THE MAXIMUM VERTICAL |
| CLEARANCE BETWEEN THE TOP OF THE POOL |
| STRUCTURE AND THE BOTTOM OF THE BARRIER |
| SHALL BE 4 INCHES. |
| |
| 424.2.17.1.2 THE BARRIER MAY NOT HAVE |
| ANY GAPS, OPENINGS, INDENTATIONS, |
| PROTRUSIONS, OR STRUCTURAL COMPONENTS |
| THAT COULD ALLOW A YOUNG CHILD TO CRAWL |
| UNDER, SQUEEZE THROUGH, OR CLIMB OVER |
| THE BARRIER AS HEREIN DESCRIBED BELOW. |
| ONE END OF A REMOVABLE CHILD BARRIER |
| SHALL NOT BE REMOVABLE WITHOUT THE AID |
| OF TOOLS.OPENINGS IN ANY BARRIER SHALL |
| NOT ALLOW PASSAGE OF A 4-INCH DIAMETER |
| SPHERE. |
| |
| 424.2.17.1.6 MAXIMUM MESH SIZE FOR CHAIN |
| LINK FENCES SHALL BE A 2-1/4 INCH SQUARE |
| UNLESS THE FENCE IS PROVIDED WITH SLATS |
| FASTENED AT THE TOP OR BOTTOM WHICH |
| REDUCE THE OPENINGS TO NO MORE THAN |
| 1-3/4 INCHES. |
| |
| 424.2.17.1.7 WHERE THE BARRIER IS |
| COMPOSED OF DIAGONAL MEMBERS, THE |
| MAXIMUM OPENING FORMED BY THE DIAGONAL |
| MEMBERS SHALL BE NO MORE THAN 1-3/4 |
| INCHES. |
| |
| 424.2.17.1.8 ACCESS GATES, WHEN |
| PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF |
| ?424.2.17.1.1 THROUGH 424.2.17.1.7 AND |
| SHALL BE EQUIPPED WITH A SELF-LATCHING |
| LOCKING DEVICE LOCATED ON THE POOL SIDE |
| OF THE GATE.WHERE THE DEVICE |
| RELEASE IS LOCATED NO LESS THAN 54 |
| INCHES FROM THE BOTTOM OF THE GATE, THE |
| DEVICE RELEASE MECHANISM MAY BE LOCATED |
| ON EITHER SIDE OF THE GATE AND SO PLACED |
| THAT IT CANNOT BE REACHED BY A YOUNG |
| CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE.GATES |
| THAT PROVIDE ACCESS TO THE SWIMMING POOL |
| MUST OPEN OUTWARD AWAY FROM THE POOL. |
| THE GATES AND BARRIER SHALL HAVE NO |
| OPENING GREATER THAN 1/2 INCH WITHIN 18 |
| INCHES OF THE RELEASE MECHANISM. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| |