Plan Review Notes
Plan Review Notes For Permit 05070533
Permit Number 05070533
Review Stop B
Sequence Number 1
Notes
Date Text
2005-07-13 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- MULE-HIDE BITUMEN ROOF SYSTEM
 SUBMITTED DOESN'T WORK. IT'S LIMITED BY
 LIMITATION #9 WHICH DOESN'T ALLOW
 ENHANCED FASTENING TO INCREASE THE
 UPLIFT VALUE AT CORNERS AND PERIMETER
 ZONES. PROVIDE ANOTHER SYSTEM THAT IS
 NOT LIMITED BY LIMITATION #9. (SEE TABLE
 1606.2B FBC 2001 FOR DESIGN PRESSURES AT
 CORNERS AND PERIMETER AREAS)
  
 2- CLEARLY SPECIFY ROOF TILE FASTENING.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC
 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.