Plan Review Notes
Plan Review Notes For Permit 05061710
Permit Number 05061710
Review Stop B
Sequence Number 1
Notes
Date Text
2005-06-28 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05061710
 ADD: 3801NORTHSHORE DRIVE
 CONT:PIGNATO-MEEKS
 TEL: (561)585-3630
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: REVIEWED
  
 PROVISO:
 1507.3.8. ASPHALT SHINGLES LOW
 SLOPE ROOFING, UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 UP TO 4:12,
 UNDERLAYMENT SHAL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER LAPPING SUCCESSIVE SHEETS
 19 INCHES AND FASTENED SUFFICIENTLY TO
 STAY IN PLACE.
  
 N.O.A.-LIMITATIONS- SHALL NOT BE
 INSTALLED ON ROOF MEAN HEIGHTS IN ACCESS
 OF 33 FT.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026