2005-07-25 00:00:00BUILDING REVIEW PROVISO:
 1-SHUTTERS UNDER A SEPARATE PERMIT.
 2- NEED WORST CASE SCENARIO ENERGY CALCS
 3- CLARIFY DOOR WINDOW/SCHEDULE. DON'T
 MIX TOGETHER DOOR/WINDOW SYMBOLS.
 4- REVISE DETAIL 5/D1: HTS20 CONNECTOR
 CAN'T SUPPORT GIRDER TRUSS.
 5- UPDATE HUS26 NAIL SIZE.SEE CATALOGUE
 6- REVISE CONNECTOR SPECIFIED AT ENTRY
 PORCH TO MATCH DETAILS 5/D1 AND 6/D1.
 7- RE-SUBMIT PRODUCT APPROVAL FOR:
 A)ROOF TILE, B)SINGLE HUNG WINDOWS,
 C)FIXED WINDOWS.
 8- SHEET A-5 SHEAR VALUES NOTE: PROVIDE
 HAND CALCULATIONS. WHY USING TIMBER
 CONSTRUCTION MANUAL FOR TAPCON VALUES?