2005-08-13 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1. SHT S-6 NOT APPROVED. NO GLUED/PASTED
 SHEETS ALLOWED ON SIGNED/SEALED PLANS.
 SECTION 104.2.1.3.
 2. SHT S-6 THE WASH MACHINE SHALL
 CONNECT TO THE GREASE DRAIN DOWNSTREAM
 OF THE TRAP OF THE TRENCH DRAIN. SECTION
 1002.1.
 3. SHT S-6 WATER HAMMER ARRESTORS ARE
 REQUIRED AT THE WASH MACHINE. SECTION
 604.9
 4. SHT S-6 SHUT OFF VALVES ARE REQUIRED
 ON THE WATER SUPPLY PIPE TO EACH HOSE
 BIBB. SECTION 606.2(2).
  
 REVIEW BY KEN STEVENS