2005-07-07 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- SHEET T1: UPDATE GENERAL NOTES. SEE
 COMMENTS ON PLANS.
  
 3- DESIGN PARAMETERS: WHY MINIMUM SOIL
 BEARING PRESSURE IS : NA?
  
 4- PROVIDE COMPLETE SPECS AND LISTING
 FORBBQ DESIGNED TO BE INSTALLED IN
 PORCH. SEC. 104.2.1.2 CITY AMENDMENTS TO
 FBC 2001 AND SEC. 2808 FBC 2001.
  
 5- PROVIDE UL LISTING AND SPECS FOR
 FIREPLACE. SEC. 2806 FBC 2001.
  
 6- SHEET A1: FOOTING DETAIL BETWEEN GOLF
 CART AND THEATER DOESN'T MATCH DETAIL 5.
 REVISE AS REQUIRED.
  
 7- DOOR LEADING DIRECTLY INTO A SLEEPING
 ROOM IS NOT ALLOWED. PREVIOUS PLANS
 SHOWED BUILT OUT FLOOR LEVELS AND
 THEATER CONFIGURATION. THIS PLAN SHOWS A
 ROOM WITH A CLOSET. PROVIDE THEATER SET
 UP OR CONSPICUOSLY WRITE UNDER THEATER
 THAT ROOM IS NOT DESIGNED FOR SLEEPING
 PURPOSES. SEC. 411.2.8 FBC 2001.
  
 8- PROVIDE FULL BATHROOM WITH DOOR THAT
 ALLOWS 29" MIN. CLEAR OPENING AS
 REQUIRED BY SEC. 11-11 FBC 2001.
  
 9- PLANS ARE SPECIFYING LOT 20. THIS
 PLANS ARE FOR LOT 3. REVISE AS REQUIRED.
  
 10- REVISE/UPDATE ALL TRUSS ANCHOR
 SPECIFYING SAME SIZE AND NUMBER OF NAILS
 AS SHOWN ON CATALOGUE THAT WAS REVISED
 TO COMPLY WITH SEC. 1609.4.3 FBC 2001.
 OTHERWISE, PROVIDE TESTING & ENGINEERING
 FOR NAIL SIZE AND NUMBER THAT DIFFER
 FROM THOSE ALREADY TESTED AND PUBLISHED
 BY THE MANUFACTURER. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 11- CONNECTOR THD210 IS A WOOD TO WOOD
 CONNECTOR. SEE CATALOGUE FOR PROPER
 MASONRY CONNECTORS AND REVISE AS REQ'D.
  
 12- CLARIFY WHY USING ONLY AN F
 CONNECTOR TO SUPPORT END OF GIRDER TRUSS
 ABOVE BEDROOM #3 ENTRY. SEE PLAN FOR
 COMMENTS. SPECIFY CALCULATED UPLIFT AT
 THIS POINT. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 13- CLEARLY SPECIFY MULLIONS AND ANCHORS
 FOR BIG FIXED WINDOWS AT LIVING ROOM
 THAT MEET THE CALCULATED DESIGN
 PRESSURES. SEE PRODUCT APPROVAL. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 14- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) SLIDING GLASS DOORS. DADE COUNTY NOA
 DOESN'T MATCH INFORMATION SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL.
  
 B)WINDOW MULLIONS SPECIFIED. SEE
 COMMENT #13 ABOVE.
  
 C) CASEMENT WINDOWS: NEED THE FLORIDA
 PRODUCT APPROVAL. NOA ALONE IS NOT
 ACCEPTABLE.
  
 15- SOIL TEST REPORT SUBMITTED IS FOR
 LOT 20. NEED ONE FOR LOT 3.
  
 16- SURVEY SUBMITTED DOESN'T MATCH FLOOR
 PLANS. REVISE AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.