Plan Review Notes
Plan Review Notes For Permit 05051929
Permit Number 05051929
Review Stop B
Sequence Number 1
Notes
Date Text
2005-07-12 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- UPDATE GENERAL NOTES IN SHEET T1. SEE
 CHAPTER 19 AND 35 FBC 2001 FOR PROPER
 STANDARD REFERENCE AND EDITION. ALSO,
 SEE SEC. 2405.2 FBC 2001 AND REVISE
 SAFETY GLAZING NOTE AS REQUIRED.
  
 3- DESIGN PARAMETERS: WHY MINIMUM SOIL
 BEARING PRESSURE IS : NA?.
  
 4- PROVIDE COMPLETE BBQ SPECS AND
 LISTING FOR INSTALLATION IN PORCH. SEC.
 2808 FBC 2001.
  
 5- FOOTING BETWEEN GARAGE AND CLUB ROOM
 DON'T MATCH DETAIL 5. REVISE AS REQUIRED
  
 6- REVISE/UPDATE ALL TRUSS ANCHORS NAIL
 SIZE AND NUMBER TO MATCH CATALOGUE THAT
 WAS REVISED TO COMPLY WITH SEC. 1609.4.3
 FBC 2001. PROVIDE TESTING & ENGINEERING
 FOR TYPE AND NUMBER OF NAILS THAT DIFFER
 FROM THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 7- CONNECTOR THD210 IS A WOOD TO WOOD
 CONNECTOR. SEE CATALOGUE FOR PROPER
 MASONRY CONNECTOR AND REVISE AS REQ'D.
  
 8- SPECIFY MULLION SIZE AND ANCHORS FOR
 FIXED WINDOWS AT LIVING ROOM. SIZE OF
 MULLION SHOWN ON PRODUCT APPROVAL
 SUBMITTED DOESN'T RESIST THE DESIGN
 PRESSURES CALCULATED ON PLANS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 9- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) SLIDING GLASS DOORS. DADE COUNTY NOA
 AND FLORIDA REPORT DON'T CORRESPOND TO
 EACH OTHER.
  
 B) WINDOW MULLION SIZE AS SPECIFIED ON
 PLANS FOR LIVING ROOM WINDOWS.
  
 C) CASEMENT WINDOWS. NEED THE FLORIDA
 PRODUCT APPROVAL PART. MAKE SURE DADE
 COUNTY NOA MATCHES FLORIDA REPORT AND
 ASSEMBLY SHOWN ON PLANS.
  
 D) ROOF TILE. NEED FLORIDA PRODUCT
 APPROVAL. MAKE SURE REPORT SUBMITTTED IS
 THE SAME ONE SUBMITTED FOR FLORIDA
 PRODUCT APPROVAL.
  
 10- OWES #206.76 FOR UPDATED VALUATION.
 GUEST ROOM WAS NOT CONSIDERED IN A/C
 AREA DECLARED IN APPLICATION.
  
 11- SPECIFY COLUMNS AT MASTER BEDROOM
 BAY WINDOW. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001. SEE SHEET A1.
  
 12- DETAIL E/A3: CLARIFY WHY USING 6"
 BOLTS INTO CONCRETE. THERE IS NOT
 CONCRETE TO ATTACH TO. REVISE AS REQ'D.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.
  