Plan Review Notes
Plan Review Notes For Permit 05051674
Permit Number 05051674
Review Stop P
Sequence Number 1
Notes
Date Text
2005-06-14 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1.ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
 2. PIPING SCHEMATIC DOES NOT REFLECT THE
 SPECIFICATIONS OR PIPING DIAGRAM. PIPING
 DIAGRAM INDICATES 2 PUMPS AND SCHEMATIC
 ONLY SHOWS ONE. SPECIFICATIONS DO NOT
 INDICATE A POOL HEATER, OR VACUUM LINE,
 BUT SCHEMATIC SHOWS BOTH. SCHEMATIC
 SHOWS A VACUUM LINE, BUT SPECIFICATIONS
 AND PIPING DIAGRAM DO NOT SHOW A VACUUM.
 PLEASE CORRELATE SCHEMATIC WITH PIPING
 DIAGRAM AND SPECIFICATIONS. SECTION
 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  