2005-05-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1. SANITARY RISERS ARE ENGINEERED SYSTEM | | (SOVENT) AND ALL CHANGES TO THE | | ENGINEERED SYSTEM SHALL BE DONE BY AN | | ENGINEER. SUBMIT CHANGES TO THE SOVENT | | SYSTEM, SIGNED, SEALED, & DATED BY AN | | ENGINEER IN ISOMETRIC FORM SHOWING ALL | | CONNECTIONS TO THE STACKS AND INDICATE | | STACK NUMBER MOVED FIXTURES OR ADDED | | FIXTURES ARE CONNECTED TO. SECTION | | 104.3.1.1. | | 2. SHTS A-1 & A-2 STATE "DROP EXISTING | | FIREPLACE" PLEASE CLARIFY. DOES THIS | | MEAN THE FIREPLACE WILL BE DELETED? | | SECTION 104.2.1. | | 3. SHT A-1 IN THE INSTALLATION OR | | REMOVAL OF ANY PART OF A DRAINAGE | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | SECTION 704.5 - THE DEMO'D/REMOVED | | DRAINAGE PIPE WILL BE FIELD INSPECTED | | PRIOR TO COVERING. SECTION 105.6. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|