2005-07-06 00:00:00SECOND CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- THERE ARE COMPANIES WHO HAVE DESIGNED
 BBQ'S SPECIFICALLY FOR LANAI OR PORCH
 AND THEY REQUIRE EXHAUST HOOD. THE
 BUILDING OFFICIAL NEEDS TESTING AND
 ENGINEERING TO SUPPORT STATEMENT ON
 LETTER THAT EXHAUST HOOD IS NOT
 REQUIRED. ALSO, LETTER IS NOT ACCEPTABLE
 BECAUSE IT'S SIGNED BY NOBODY.
  
 3- CLARIFY IF USING STORM SHUTTERS OR
 DOORS WITH IMPACT GLAZING. SLIDING GLASS
 DOORS PRODUCT APPROVAL SUBMITTED HAVE
 IMPACT GLAZING.
 CLARIFY WHICH OPENINGS WILL HAVE
 SHUTTERS OR NOT.
 PROVIDE COMPLETE SHUTTERS INFORMATION OR
 APPLY UNDER A SEPARATE PERMIT. STILL,
 CLARIFY OPENINGS TO HAVE SHUTTERS.
  
 4- SHEET A3: A) REVISE/UPDATE TRUSS
 ANCHOR SCHEDULE (NOT DONE FROM PREVIOUS
 CHECKLIST). SEE LATEST CATALOGUE THAT
 WAS REVISED TO COMPLY WITH SEC. 1609.4.3
 FBC 2001. OTHERWISE, PROVIDE TESTING AND
 ENGINEERING FOR NAIL SIZE AND NUMBER
 THAT DIFFER FROM THOSE TESTED AND
 PUBLISHED BY THE MANUFACTURER. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 B) CONNECTOR THD210 IS A WOOD TO WOOD
 CONNECTOR. NEED MASONRY HANGER. SEE
 CATALOGUE FOR PROPER MASONRY CONNECTOR.
  
 C) DETAIL E/A3: CLARIFY WHY HAVING 6"
 BOLTS INTO CONCRETE IF THERE IS NOT
 CONCRETE WALL TO BE ATTACHED TO.SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 5- A)FLORIDA PRODUCT APPROVAL FOR CORNER
  
 SLIDING GLASS DOORS AND DADE COUNTY NOA
 SUBMITTED DON'T CORRESPOND TO EACH OTHER
  
 B) CLARIFY IF USING DOORS WITH IMPACT
 GLASS OR NOT AND PROVIDE CORRECT FLORIDA
 PRODUCT APPROVAL.
  
 6- MULLION SIZE SPECIFIED FOR FIXED
 WINDOWS AT LIVING ROOM IS NOT GOOD. SEE
 DESIGN PRESSURES ON PLANS AND ON
 PRODUCT APPROVAL. REVISE MULLION SIZE
 AND ANCHOR AS REQUIRED AND PROVIDE
 PROPER FLORIDA PRODUCT APPROVAL FOR EACH
 TYPE OF MULLIONS.
  
 7- DADE COUNTY NOA SUBMITTED FOR
 CASEMENT WINDOWS DOESN'T MATCH NOA
 SUBMITTED FOR FLORIDA PRODUCT APPROVAL.
 PROVIDE MATCHING NOA AND VERIFY THAT
 ASSEMBLY MATCHES ONE SHOWN ON PLANS TOO.
  
 8- REAR ELEVATION DOESN'T MATCH FLOOR
 PLAN. SEE WINDOWS SPECIFIED ON PLAN FOR
 LIVING ROOM AREA AND REVISE AS REQUIRED.
  
 9- PROVIDE FLORIDA PRODUCT APPROVAL FOR
 IMPACT GLASS CASEMENT WINDOW AT
 BREAKFAST AREA.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.
  