2005-11-17 00:00:00 | BUILDING SUBMITTAL CHECKLIST: |
| 1- A) ENERGY CALCULATIONS WERE REVISED. |
| NEED TO USE FBC 2001 FORM NOT FBC 2004 |
| FORM. PROVIDE CORRECT ENERGY CALCS FORM. |
| B) ENERGY CALCULATIONS NEED TO BE |
| CALCULATED FOR WORST CASE SCENARIO OR |
| SITE SPECIFIC ORIENTATION. CALCULATIONS |
| SUBMITTED ARE NOT FOR SITE SPECIFIC |
| ORIENTATION FOR THIS HOUSE. IT DOESN'T |
| MATCH HOUSE ORIENTATION. SEE SURVEY AND |
| PROVIDE CORRECT SITE SPECIFIC |
| ORIENTATION. |
| |
| 2- A) REVISE ROOF FRAMING PLAN AT ENTRY |
| AREA. PROVIDE CORRECT FRAMING PLAN AND |
| CORRESPONDING CONNECTOR. THIS DWG WAS |
| NOT SUBMITTED WITH THIS SUBMITTAL. |
| B) REVISE TRUSS ANCHOR SCHEDULE. |
| SPECIFY CORRECT SIZE AND NUMBER OF NAILS |
| FOR CONNECTOR HUS26. DWG NOT SUBMITTED. |
| |
| 3- PROVIDE CORRECT INFORMATION FOR FIRE |
| RATED DOOR AT ATRIUM: |
| A) DRAWINGS ARE FOR "OUTSWING" DOOR, |
| WHILE DADE COUNTY NOA IS FOR "INSWING" |
| DOOR. PROVIDE MATCHING INFORMATION. |
| B) NEED 8'-0" HIGH DOOR AS SPECIFIED |
| ON ARCHITECT'S PLANS. |
| |
| 4- REVISED DRAWINGS AND ENERGY |
| CALCULATIONS WILL BE SUBJECT TO REVISION |
| FEES AS APPLICABLE. |
| |
| JULIO GOMEZ |
| BUILDING PLANS EXAMINER |
| (561)805-6712 |