Plan Review Notes For Permit 05040907 |
Permit Number |
05040907 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2005-06-08 00:00:00 | BUILDING REVIEW PROVISO: | | 1- SHUTTERS UNDER SEPARATE PERMIT. | | 2- USING SAME ENERGY CALCULATIONS FOR | | THIS MODEL, THEREFORE, NEED ENERGY | | CALCULATIONS FOR WORST CASE SCENARIO. | | REVISE ENERGY CALCS AS REQUIRED. | | 3- REVISE DOOR SCHEDULE TO MATCH SIZES & | | TYPE OF DOORS SHOWN ON PLANS/ELEVATIONS. | | 4- DETAIL 5/D-1: CONNECTOR HTS20 CAN'T | | SUPPORT BEAM. SPECIFY HANGER OR CLARIFY | | HOW IS BEAM SUPPORTED ON LEDGER. | | 5- TRUSS ANCHOR SCHEDULE: UPDATE NAIL | | SIZE USED FOR HUS26 CONNECTOR. | | 6- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT ENTRY PORCH TO MATCH | | DETAILS 5 & 6 OF DRAWING D-1. | | 7- PROVIDE PRODUCT APPROVAL FOR 9'-0" | | WIDE SLIDING GLASS DOORS. | | 8- SHEET A-5.0 SHEAR VALUES NOTE: | | A) PROVIDE HAND CALCULATIONS. SECTION | | 104.2.1.2 CITY AMENDEMNTS TO FBC 2001. | | B) WHY USING TIMBER CONSTRUCTION MANUAL? | | SEE CHAPTER 23 FBC 2001. | | C) WHY USING TIMBER MANUAL TO CALCULATE | | TAPCON VALUES? |
|