2005-08-16 00:00:00BUILDING REVISION REVIEW CHECKLIST:
 1- UNABLE TO FIND THE REVISIONS. EXCEPT
 FOR ADDITIONAL DETAILS ON SHEET D2. WHAT
 WAS THE REVISION FOR?.
  
 2- PROVIDE INFORMATION REQ'D ON PROVISO
 DATED 6-30-05.
  
 A) APPLY FOR SHUTTERS PERMIT.
  
 B) PROVIDE REVISED ENERGY CALCS FOR
 WORST CASE SCENARIO.
  
 C) REVISE DOOR/WINDOW SCHEDULE TO MATCH
 PLANS WITHOUT MIXMATCHING EACH OTHER.
 EG: DOORS ON WINDOW SCHEDULE & VICEVERSA
  
 D) REVISE DETAIL5/D-1: HTS20 CAN'T
 SUPPORT GIRDER TRUSS.
  
 E) TRUSS ANCHOR SCHEDULE: UPDATE NAIL
 SIZE FOR HUS26. SEE CATALOGUE.
  
 F) ROOF FRAMING PLAN: REVISE CONNECTORS
 AT ENTRY PORCH TO MATCH DETAILS 5 AND 6
 OF DRAWINGS D-1.
  
 G) PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 * 9'-0" WIDE SLIDING GLASS DOORS.
 **8'-0" HIGH ENTRY DOORS.
  
 H) SHEET A-5.0 SHEAR VALUE NOTE: PROVIDE
 CALCULATED HAND CALCULATIONS FOR SHEAR
 VALUES FOR NAILS AND TAPCONS AS
 SPECIFIED ON THE NOTE. WHY USING TIMBER
 MANUAL TO CALCULATE TAPCON VALUES?
 SPECIFIED EDITION OF THE MANUAL USED.
 SECTION 104.2.1.2 CITY AMENDMENTS TO FBC
  
 I) PROVIDE REVISED SOIL TEST REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.