2005-09-01 00:00:00 | SUBMITTAL BUILDING REVIEW CHECKLIST: |
| 1- SEPARATE PERMIT FOR SHUTTERS HAS NOT |
| BEEN APPLIED FOR YET. |
| |
| 2- ENERGY CALCULATIONS WERE REVISED. NOW |
| CEILING FAN CREDIT WAS TAKEN. THEREFORE, |
| NEED TO REVISE ELECTRICAL PLAN SHOWING |
| SIZE OF CEILING FANS, INCLUDING FANS IN |
| THE GREAT ROOM AS REQUIRED BY TABLE 6-6 |
| OF CHAPTER 13 FBC 2001. |
| |
| 3- ROOF FRAMING PLAN NEEDS TO BE REVISED |
| AT ENTRY PORCH AREA TO MATCH FOUNDATION |
| PLAN AND FLOOR PLAN. NOTICE THAT |
| CONCRETE BEAM DOESN'T EXTEND ALL THE WAY |
| INSIDE TO THE FOYER AREA. CONCRETE BEAM |
| IS ONLY AT ENTRY PORCH AREA. REVISE ROOF |
| FRAMING PLAN AS REQUIRED AND SPECIFIY |
| CORRESPONDING CONNECTORS. SECTION |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| |
| 4- TRUSS ANCHOR SCHEDULE: REVISE NUMBER |
| OF NAILS SPECIFIED FOR CONNECTOR HUS26. |
| SEE 2005 CATALOGUE. |
| |
| 5- ONE HOUR FIRE RATED DOOR AT ATRIUM |
| PRODUCT APPROVAL SUBMITTED IS FOR |
| OUTSWING DOOR. PLANS SHOW INSWING DOOR. |
| REVISE AS REQUIRED. |
| |
| 6- SPECIFY WINDOW MULLION AND ANCHORS |
| FOR FIXED WINDOWS AT GREAT ROOM. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| |
| 7- PROVIDE PRODUCT APPROVAL FOR WINDOW |
| MULLION SPECIFIED FOR FIXED WINDOWS AT |
| GREAT ROOM. |
| |
| 8- ALL REVISED DRAWINGS WILL BE SUBJECT |
| TO THE REVISION FEES. |
| |