Date |
Text |
2005-07-07 00:00:00 | BUILDING REVIEW CHECKLIST: |
| 1- NEED RECORDED NOTICE OF COMMENCEMENT. |
| |
| 2- SHEET T1: A) UPDATE GENERAL NOTES. |
| SEE COMMENTS ON PLANS. |
| |
| B) DESIGN PARAMETERS: WHY MIN. SOIL |
| BEARING PRESSURE IS : NA?. |
| |
| 3- PROVIDE COMPLETE SPECS FOR BBQ WHICH |
| IS SPECIFICALLY DESIGNED FOR A PORCH. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| |
| 4- PROVIDE COMPLETE INFORMATION FOR |
| SHUTTERS OR APPLY FOR SEPARATE PERMIT. |
| |
| 5- SPECIFY SAFETY GLASS FOR WINDOWS AT |
| HER AND HIS BATH. SEE PLANS AND SEC. |
| 2405.2.1(2) |
| |
| 6- PROVIDE COMPLETE SPECS AND UL LISTING |
| FOR PORCH FIREPLACE. SEC. 2806 FBC 2001. |
| |
| 7- SHEET A3: A) TRUSS ANCHOR SCHEDULE: |
| CONNECTOR THD210 IS A WOOD TO WOOD |
| CONNECTOR. REVISE AS REQUIRED. SEE |
| CATALOGUE FOR PROPER MASONRY CONNECTOR. |
| |
| B) ALL CONNECTORS TO SPECIFY SIZE AND |
| NUMBER OF NAILS AS SHOWN ON LATEST |
| CATALOGUE WHICH WAS REVISED TO COMPLY |
| WITH SEC. 1609.4.3 FBC 2001. OTHERWISE |
| PROVIDE TESTING AND ENGINEERING FOR SIZE |
| AND NUMBER OF NAILS THAT DIFFER FROM |
| THOSE ALREADY TESTED AND PUBLISHED BY |
| MANUFACTURER. SEC. 104.2.1.2 CITY |
| AMENDMENTS TO FBC 2001. |
| |
| C) CLARIFY WHY USING ONLY AN F CONNECTOR |
| TO SUPPORT END OF GIRDER TRUSS ABOVE |
| BEDROOM #3 ENTRY. SEE PLAN FOR COMMENTS. |
| SPECIFY CALCULATED UPLIFT. SECTION |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| |
| 8- PROVIDE FLORIDA OR APPLY FOR LOCAL |
| PRODUCT APPROVAL FOR: |
| A) SLIDING GLASS DOORS. (CLARIFY IF |
| USING IMPACT DOORS OR NOT). |
| |
| B) WINDOW MULLIONS REQUIRED FOR LARGE |
| FIXED WINDOWS AT LIVING ROOM. CLEARLY |
| SPECIFY SIZE AND ANCHORS TO BE USED. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| ALSO, CLEARLY SPECIFY MULLION SIZE AND |
| FASTENERS FOR OTHER MULLIONS. |
| |
| C) CASEMENT WINDOWS DADE COUNTY NOA THAT |
| MATCHES ONE SUBMITTED FOR FLORIDA |
| PRODUCT APPROVAL. |
| NOTE: ASSEMBLIESSUBMITTED ALSO NEED TO |
| MATCH THOSE SHOWN ON PLANS. |
| |
| D) CASEMENT WINDOW WITH IMPACT GLASS AS |
| SHOWN ON BREAKFAST AREA TO PROVIDE |
| EMERGENCY EGRESS. |
| |
| 9- OWES $360.70 FOR ADDITIONAL GUEST |
| SUITE VALUATION AND RADON FEES. |
| |
| 10- REVISE ENERGY CALCULATIONS TO |
| INCLUDE GUEST SUITE. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| JULIO GOMEZ AT (561)805-6712. |
| |