2005-07-22 00:00:00 | CHECKLIST: |
| 1- ROOF LOADS CHART IN SHEET A2 IS |
| WRONG. IT'S NOT TAKING INTO |
| CONSIDERATION THE ATTIC LIVE LOAD |
| REQUIRED BY TABLE 1604.1 FBC 2001. |
| (30PSF LIVE LOAD FOR STORAGE OR 10PSF |
| LIVE LOAD WITHOUT STORAGE). |
| |
| 2- STEPS AT ENTRY PORCH AND GARAGE DON'T |
| COMPLY WITH SECTION 1007.3.1EXCEPTION |
| #1. IT DOESN'T MEET THE REQUIRED RISER |
| TREAD RATIO. |
| |
| 3- REVISE ENERGY CALCULATIONS AGAIN: |
| A) IF THEY ARE PREPARED BY THE |
| ARCHITECT, THEY NEED TO BE SIGNED, |
| SEALED AND DATED AS REQUIRED BY CHAPTER |
| 481 FLORIDA STATUTES. |
| B) OVERHANG LENGTH AND HEIGHT ARE |
| INCORRECT. SEE SEC. 601.2.A.3 CHAPTER 13 |
| OF FBC 2001. |
| C) OWNER/AGENT TO SIGN AND DATE BOTTOM |
| OF FORM. |
| D) SLAB ON GRADE PERIMETER CALCULATION |
| DOESN'T MATCH PLANS. |
| E) NEED ADJACENT CEILING AREA. |
| |
| 4- CLEARLY IDENTIFY SINGLE HUNG WINDOWS |
| TO BE USED TO VERIFY COMPLIANCE WITH THE |
| CALCULATED DESIGN PRESSURES SINCE |
| PRODUCT APPROVAL SUBMITTED HAS SOME |
| WINDOWS THAT DON'T MEET THOSE LOADS. |
| |
| 5- SPECIFICATIONS FOR WIRE LATH IN THE |
| FASTENER SCHEDULE DON'T MATCH |
| SPECIFICATIONS SHOWN ON PORCH SECTION. |
| REVISE AS REQUIRED. |
| |
| 6- STAIR SECTION. CLEARLY INDICATE |
| FIREBLOCKING IN STAIRWAY SECTION AS |
| REQUIRED BY SEC. 2305.1.4 FBC 2001. |
| (THERE WAS NOT LETTER ATTACHED WITH |
| SUBMITTAL). |
| |